Randomized comparison of atrioventricular node re-entry tachycardia and atrial flutter catheter ablation with and without fluoroscopic guidance: ZeroFluoro study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F22%3A00077723" target="_blank" >RIV/00159816:_____/22:00077723 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/22:00128480
Výsledek na webu
<a href="https://academic.oup.com/europace/article/24/10/1636/6670970?login=true" target="_blank" >https://academic.oup.com/europace/article/24/10/1636/6670970?login=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euac049" target="_blank" >10.1093/europace/euac049</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Randomized comparison of atrioventricular node re-entry tachycardia and atrial flutter catheter ablation with and without fluoroscopic guidance: ZeroFluoro study
Popis výsledku v původním jazyce
Background Interventional cardiology procedures may expose patients and staff to considerable radiation doses. We aimed to assess whether exposure to ionizing radiation during catheter ablation of supraventricular tachycardia (SVT) can be completely avoided. Methods In this prospective randomized study, patients with SVT (atrioventricular re-entrant tachycardia n = 94, typical atrial flutter n = 29) were randomly assigned in a 1:1 ratio to catheter ablation with conventional fluoroscopic guidance (CF group) or with the EnSite Precision mapping system [zerofluoro (ZF) group]. Acute procedural parameters, increased stochastic risk of cancer incidence and 6-month follow-up data were assessed. Results Between May 2019 and August 2020, 123 patients were enrolled. Clinical parameters were comparable. Median procedural time was 60.0 and 58.0 min, median fluoroscopy time and estimated median effective dose were 240 s vs. 0 and 0.38 mSv vs. 0 and arrhythmia recurrence was 5% and 7.9% in the CF and ZF groups, respectively. The acute success rate was 98.4% in both groups. No procedure-related complications were reported. At an average age of 55.5 years and median radiation exposure of 0.38 mSv, the estimate of increased incidence was approximately 1 in 14 084. The estimated mortality rate was 1 per 17 857 exposed persons. Conclusions The procedural safety and efficacy of the zero-fluoroscopic approach are similar to those of conventional fluoroscopy-based ablation for atrioventricular nodal re-entrant tachycardia and atrial flutter. Under the assumption of low radiation dose, the excessive lifetime risk of malignancy in the CF group due to electrophysiology procedure is reasonably small, whilst totally reduced in zero fluoroscopy procedures.
Název v anglickém jazyce
Randomized comparison of atrioventricular node re-entry tachycardia and atrial flutter catheter ablation with and without fluoroscopic guidance: ZeroFluoro study
Popis výsledku anglicky
Background Interventional cardiology procedures may expose patients and staff to considerable radiation doses. We aimed to assess whether exposure to ionizing radiation during catheter ablation of supraventricular tachycardia (SVT) can be completely avoided. Methods In this prospective randomized study, patients with SVT (atrioventricular re-entrant tachycardia n = 94, typical atrial flutter n = 29) were randomly assigned in a 1:1 ratio to catheter ablation with conventional fluoroscopic guidance (CF group) or with the EnSite Precision mapping system [zerofluoro (ZF) group]. Acute procedural parameters, increased stochastic risk of cancer incidence and 6-month follow-up data were assessed. Results Between May 2019 and August 2020, 123 patients were enrolled. Clinical parameters were comparable. Median procedural time was 60.0 and 58.0 min, median fluoroscopy time and estimated median effective dose were 240 s vs. 0 and 0.38 mSv vs. 0 and arrhythmia recurrence was 5% and 7.9% in the CF and ZF groups, respectively. The acute success rate was 98.4% in both groups. No procedure-related complications were reported. At an average age of 55.5 years and median radiation exposure of 0.38 mSv, the estimate of increased incidence was approximately 1 in 14 084. The estimated mortality rate was 1 per 17 857 exposed persons. Conclusions The procedural safety and efficacy of the zero-fluoroscopic approach are similar to those of conventional fluoroscopy-based ablation for atrioventricular nodal re-entrant tachycardia and atrial flutter. Under the assumption of low radiation dose, the excessive lifetime risk of malignancy in the CF group due to electrophysiology procedure is reasonably small, whilst totally reduced in zero fluoroscopy procedures.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000868" target="_blank" >EF16_019/0000868: Molekulární, buněčný a klinický přístup ke zdravému stárnutí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
1532-2092
Svazek periodika
24
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
1636-1644
Kód UT WoS článku
000841952900001
EID výsledku v databázi Scopus
—