Implant Preference and Clinical Outcomes of Patients with Staged Bilateral Total Knee Arthroplasty: All-Polyethylene and Contralateral Metal-Backed Tibial Components
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F23%3A00079466" target="_blank" >RIV/00159816:_____/23:00079466 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/23:00132679 RIV/00216305:26210/23:PU149732
Výsledek na webu
<a href="https://www.mdpi.com/2077-0383/12/23/7438" target="_blank" >https://www.mdpi.com/2077-0383/12/23/7438</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/jcm12237438" target="_blank" >10.3390/jcm12237438</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Implant Preference and Clinical Outcomes of Patients with Staged Bilateral Total Knee Arthroplasty: All-Polyethylene and Contralateral Metal-Backed Tibial Components
Popis výsledku v původním jazyce
Numerous studies have compared metal-backed components (MBTs) and all-polyethylene tibial components (APTs), but none of them specifically analysed the clinical results and the overall patient preference in patients who had undergone a staged bilateral knee replacement. The purpose of this study is to compare clinical results, perceived range of motion, and overall implant preference among patients who had undergone staged bilateral knee replacement with an APT and contralateral knee replacement with MBTs. A dataset of 62 patients from a single centre who underwent staged bilateral TKA between 2009 and 2022 was selected and retrospectively analysed. Tibial component removal was performed in three knees overall, all of which had MBTs. The mean measured Knee Score (KS) of knees with APTs was 78.37 and that of contralateral knees with MBTs was 77.4. The mean measured Function (FS) of knees with APTs was 78.22, and that of contralateral knees with MBs was 76.29. The mean flexion angle of knees with APTs was 103.8 and that for knees with MBTs was 101.04 degrees. A total of 54.8% of the patients preferred the knee that received APTs over contralateral MBTs. In our cohort, TKA with an APT in one knee and an MBT in the contralateral knee recorded similar clinical results and perceived ranges of motion. Patients in general preferred the knee that received an APT over contralateral knee with an MBT.
Název v anglickém jazyce
Implant Preference and Clinical Outcomes of Patients with Staged Bilateral Total Knee Arthroplasty: All-Polyethylene and Contralateral Metal-Backed Tibial Components
Popis výsledku anglicky
Numerous studies have compared metal-backed components (MBTs) and all-polyethylene tibial components (APTs), but none of them specifically analysed the clinical results and the overall patient preference in patients who had undergone a staged bilateral knee replacement. The purpose of this study is to compare clinical results, perceived range of motion, and overall implant preference among patients who had undergone staged bilateral knee replacement with an APT and contralateral knee replacement with MBTs. A dataset of 62 patients from a single centre who underwent staged bilateral TKA between 2009 and 2022 was selected and retrospectively analysed. Tibial component removal was performed in three knees overall, all of which had MBTs. The mean measured Knee Score (KS) of knees with APTs was 78.37 and that of contralateral knees with MBTs was 77.4. The mean measured Function (FS) of knees with APTs was 78.22, and that of contralateral knees with MBs was 76.29. The mean flexion angle of knees with APTs was 103.8 and that for knees with MBTs was 101.04 degrees. A total of 54.8% of the patients preferred the knee that received APTs over contralateral MBTs. In our cohort, TKA with an APT in one knee and an MBT in the contralateral knee recorded similar clinical results and perceived ranges of motion. Patients in general preferred the knee that received an APT over contralateral knee with an MBT.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30218 - General and internal medicine
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Clinical Medicine
ISSN
2077-0383
e-ISSN
2077-0383
Svazek periodika
12
Číslo periodika v rámci svazku
23
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
9
Strana od-do
7438
Kód UT WoS článku
001117938900001
EID výsledku v databázi Scopus
—