Absolute Frequency Measurement of the R(12) 26-0 and R(106) 28-0 Transitions in 127I2 at l=543 nm
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F06%3A%230000124" target="_blank" >RIV/00177016:_____/06:#0000124 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Absolute Frequency Measurement of the R(12) 26-0 and R(106) 28-0 Transitions in 127I2 at l=543 nm
Popis výsledku v původním jazyce
A direct phase coherent determination of the absolute frequency of the a15 component in the R(12) 26-0 and b10 component in the R(106) 28-0 transitions in 127I2 at 543 nm has been made at the International Bureau of Weights and Measures. Lasers from theCzech Metrology Institute (Czech Republic), the National Institute of Metrology (China), the Centro Nacional de Metrologia (Mexico), the Standards, Productivity and Innovation Board (Singapore), the Centre for Metrology and Accreditation (Finland), the Danish Institute of Fundamental Metrology (Denmark), the National Physical Laboratory (U.K.), and the International Bureau of Weights and Measures took part. The mean frequency values found are f(a15) = 551 579 856 480.4 kHz, uc = 4.8 kHz and f(b10) = 551580 162 397.1 kHz, uc = 4.6 kHz for the current group of lasers, where uc is the combined standard uncertainty.
Název v anglickém jazyce
Absolute Frequency Measurement of the R(12) 26-0 and R(106) 28-0 Transitions in 127I2 at l=543 nm
Popis výsledku anglicky
A direct phase coherent determination of the absolute frequency of the a15 component in the R(12) 26-0 and b10 component in the R(106) 28-0 transitions in 127I2 at 543 nm has been made at the International Bureau of Weights and Measures. Lasers from theCzech Metrology Institute (Czech Republic), the National Institute of Metrology (China), the Centro Nacional de Metrologia (Mexico), the Standards, Productivity and Innovation Board (Singapore), the Centre for Metrology and Accreditation (Finland), the Danish Institute of Fundamental Metrology (Denmark), the National Physical Laboratory (U.K.), and the International Bureau of Weights and Measures took part. The mean frequency values found are f(a15) = 551 579 856 480.4 kHz, uc = 4.8 kHz and f(b10) = 551580 162 397.1 kHz, uc = 4.6 kHz for the current group of lasers, where uc is the combined standard uncertainty.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Instrumentation and Measurement
ISSN
0018-9456
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—