Uncertainty analysis of non-coherent sampling phase meter with four parameter sine wave fitting by means of Monte Carlo
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F14%3A%230000846" target="_blank" >RIV/00177016:_____/14:#0000846 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/login.jsp?tp=&arnumber=6898395&isnumber=6898219&url=http%3A%2F%2Fieeexplore.ieee.org%2Fielx7%2F6892250%2F6898219%2F06898395.pdf%3Ftp%3D%26arnumber%3D6898395%26isnumber%3D6898219" target="_blank" >http://ieeexplore.ieee.org/xpl/login.jsp?tp=&arnumber=6898395&isnumber=6898219&url=http%3A%2F%2Fieeexplore.ieee.org%2Fielx7%2F6892250%2F6898219%2F06898395.pdf%3Ftp%3D%26arnumber%3D6898395%26isnumber%3D6898219</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CPEM.2014.6898395" target="_blank" >10.1109/CPEM.2014.6898395</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Uncertainty analysis of non-coherent sampling phase meter with four parameter sine wave fitting by means of Monte Carlo
Popis výsledku v původním jazyce
Uncertainty analysis of a very simple sampling phase meter based on four parameter sine wave fitting is presented in this paper. An uncertainty of a sample time and a measured voltage is assigned to every sampled point and a total uncertainty of a phasedifference is calculated by means of the Monte Carlo method. Results show the total uncertainty is lower than 0.5 millidegree for selected digitizer. A noise of the measured signal or the digitizer is the largest contribution to the total uncertainty.
Název v anglickém jazyce
Uncertainty analysis of non-coherent sampling phase meter with four parameter sine wave fitting by means of Monte Carlo
Popis výsledku anglicky
Uncertainty analysis of a very simple sampling phase meter based on four parameter sine wave fitting is presented in this paper. An uncertainty of a sample time and a measured voltage is assigned to every sampled point and a total uncertainty of a phasedifference is calculated by means of the Monte Carlo method. Results show the total uncertainty is lower than 0.5 millidegree for selected digitizer. A noise of the measured signal or the digitizer is the largest contribution to the total uncertainty.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7AX13031" target="_blank" >7AX13031: A quantum standard for sampled electrical measurements</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2014 Conference on Precision Electromagnetic Measurements (CPEM 2014)
ISBN
978-1-4799-5205-2
ISSN
0589-1485
e-ISSN
—
Počet stran výsledku
2
Strana od-do
335-336
Název nakladatele
IEEE
Místo vydání
Rio de Janeiro
Místo konání akce
Rio de Janeiro
Datum konání akce
1. 1. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—