Determination of Young's modulus of ceramics from flexural vibration at elevated temperatures.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F11%3A00177435" target="_blank" >RIV/68407700:21110/11:00177435 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3813/AAA.918380" target="_blank" >http://dx.doi.org/10.3813/AAA.918380</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3813/AAA.918380" target="_blank" >10.3813/AAA.918380</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Young's modulus of ceramics from flexural vibration at elevated temperatures.
Popis výsledku v původním jazyce
In this paper we describe the construction of a laboratory-made resonant apparatus for the modulated force thermomechanical analysis (mf-TMA) and estimate the uncertainty of the measurement of Young's modulus of a porcelain sample. The porcelain sample was measured while increasing the temperature up to 1000 °C/5 °Cmin-1. Thermodilatometry was performed to determine the actual dimensions of the sample in the same temperature regime. We assessed the influence of the repeatability of the directly measuredvalues, the accuracy of the used measurers and different exceptions from the ideal experimental arrangement on the Young's modulus measurement uncertainties of types A and B. We found that the majority of the total uncertainty (80 %) is determined at the room temperature. The remaining sources of uncertainty can be attributed to thermal expansion of the sample and inhomogeneity of the temperature field. The relative expanded uncertainty of the Young's m
Název v anglickém jazyce
Determination of Young's modulus of ceramics from flexural vibration at elevated temperatures.
Popis výsledku anglicky
In this paper we describe the construction of a laboratory-made resonant apparatus for the modulated force thermomechanical analysis (mf-TMA) and estimate the uncertainty of the measurement of Young's modulus of a porcelain sample. The porcelain sample was measured while increasing the temperature up to 1000 °C/5 °Cmin-1. Thermodilatometry was performed to determine the actual dimensions of the sample in the same temperature regime. We assessed the influence of the repeatability of the directly measuredvalues, the accuracy of the used measurers and different exceptions from the ideal experimental arrangement on the Young's modulus measurement uncertainties of types A and B. We found that the majority of the total uncertainty (80 %) is determined at the room temperature. The remaining sources of uncertainty can be attributed to thermal expansion of the sample and inhomogeneity of the temperature field. The relative expanded uncertainty of the Young's m
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ACTA ACUSTICA UNITED WITH ACUSTICA
ISSN
1610-1928
e-ISSN
—
Svazek periodika
97
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
1-7
Kód UT WoS článku
000286113700001
EID výsledku v databázi Scopus
—