Results of an International Comparison of Instrument Current Transformers up to 10 kA at 50 Hz Frequency
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F18%3AN0000012" target="_blank" >RIV/00177016:_____/18:N0000012 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/18:00326617
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8500821" target="_blank" >https://ieeexplore.ieee.org/document/8500821</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CPEM.2018.8500821" target="_blank" >10.1109/CPEM.2018.8500821</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Results of an International Comparison of Instrument Current Transformers up to 10 kA at 50 Hz Frequency
Popis výsledku v původním jazyce
Traceability of the current ratio is crucial for the measurement of electrical energy in revenue metering. A comparison of the AC current ratio was therefore performed within EURAMET in the time period 2012 - 2016, using a precision CT as the traveling device. The Czech Metrology Institute (CMI) as coordinator processed the measurement results of the 15 European participating laboratories. The comparison of the results for transformer ratios of (4, 5, 6, 8, 10) kA/5 A at 15 VA burden and (4 and 10) kA/5 A ratios at 5 VA burden indicates good agreement between the participating laboratories. The main differences are found for phase displacement, at least in part due to instability of the traveling standard.
Název v anglickém jazyce
Results of an International Comparison of Instrument Current Transformers up to 10 kA at 50 Hz Frequency
Popis výsledku anglicky
Traceability of the current ratio is crucial for the measurement of electrical energy in revenue metering. A comparison of the AC current ratio was therefore performed within EURAMET in the time period 2012 - 2016, using a precision CT as the traveling device. The Czech Metrology Institute (CMI) as coordinator processed the measurement results of the 15 European participating laboratories. The comparison of the results for transformer ratios of (4, 5, 6, 8, 10) kA/5 A at 15 VA burden and (4 and 10) kA/5 A ratios at 5 VA burden indicates good agreement between the participating laboratories. The main differences are found for phase displacement, at least in part due to instability of the traveling standard.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 Conference on Precision Electromagnetic Measurements (CPEM 2018)
ISBN
978-1-5386-0974-3
ISSN
2160-0171
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Paris, France
Místo konání akce
Paris, France
Datum konání akce
8. 7. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000450231900036