EURAMET supplementary comparison on calibration of RF current monitoring probe
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F21%3AN0000029" target="_blank" >RIV/00177016:_____/21:N0000029 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/0026-1394/58/1A/01004" target="_blank" >https://iopscience.iop.org/article/10.1088/0026-1394/58/1A/01004</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EURAMET supplementary comparison on calibration of RF current monitoring probe
Popis výsledku v původním jazyce
RF current monitoring probes are commonly utilized in measurements of disturbance currents of cables without making direct conductive contact with the source conductor and without modification of its circuit. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as CISPR 16-1-2 or ISO 11452-4. The RF current monitor probe comparison measurements were conducted with 8 participants; five national metrology institutes (NMIs), two designated institutes (DI) and one commercial calibration laboratory at the frequencies 0.01 MHz, 0.1 MHz, 1 MHz, 10 MHz, 100 MHz, 200 MHz, 300 MHz, 400 MHz and 500 MHz in order to obtain the transfer impedance of the RF current monitoring probe. The comparison measurements started in September 2019 and were completed in June 2020.
Název v anglickém jazyce
EURAMET supplementary comparison on calibration of RF current monitoring probe
Popis výsledku anglicky
RF current monitoring probes are commonly utilized in measurements of disturbance currents of cables without making direct conductive contact with the source conductor and without modification of its circuit. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as CISPR 16-1-2 or ISO 11452-4. The RF current monitor probe comparison measurements were conducted with 8 participants; five national metrology institutes (NMIs), two designated institutes (DI) and one commercial calibration laboratory at the frequencies 0.01 MHz, 0.1 MHz, 1 MHz, 10 MHz, 100 MHz, 200 MHz, 300 MHz, 400 MHz and 500 MHz in order to obtain the transfer impedance of the RF current monitoring probe. The comparison measurements started in September 2019 and were completed in June 2020.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrologia
ISSN
0026-1394
e-ISSN
1681-7575
Svazek periodika
58
Číslo periodika v rámci svazku
1A
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
104
Strana od-do
—
Kód UT WoS článku
000730580900004
EID výsledku v databázi Scopus
2-s2.0-85110402601