CCEM key comparison CCEM.RF-K5c.CL
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F25%3AN0000137" target="_blank" >RIV/00177016:_____/25:N0000137 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/0026-1394/62/1A/01004" target="_blank" >https://iopscience.iop.org/article/10.1088/0026-1394/62/1A/01004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0026-1394/62/1A/01004" target="_blank" >10.1088/0026-1394/62/1A/01004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CCEM key comparison CCEM.RF-K5c.CL
Popis výsledku v původním jazyce
An international measurement comparison, identified as CCEM.RF-K5c.CL, for scattering parameters and reflection coefficients by broad-band method was conducted between twenty national metrology institutes. The purpose of the comparison is to establish the calibration measurement capability of each participating laboratory. This report presents the key comparison reference values and degree of equivalence of each participant with respect to the key comparison reference values of the comparison. The participants measured seven travelling standards, an adapter, a 20 dB attenuator, a 40 dB attenuator, two matched terminations, and two flush short terminations with 3.5 mm coaxial connectors from 0.1 GHz to 33 GHz. The pilot laboratory is National Metrology Institute of Japan (NMIJ) and the supporting laboratories are Federal Institute of Metrology (METAS) and National Physical Laboratory (NPL), National Institute of Metrology (NIM), and National Institute of Standards and Technology (NIST). Most of the reported measurement results were generally consistent, while there was a small number of outlying values.
Název v anglickém jazyce
CCEM key comparison CCEM.RF-K5c.CL
Popis výsledku anglicky
An international measurement comparison, identified as CCEM.RF-K5c.CL, for scattering parameters and reflection coefficients by broad-band method was conducted between twenty national metrology institutes. The purpose of the comparison is to establish the calibration measurement capability of each participating laboratory. This report presents the key comparison reference values and degree of equivalence of each participant with respect to the key comparison reference values of the comparison. The participants measured seven travelling standards, an adapter, a 20 dB attenuator, a 40 dB attenuator, two matched terminations, and two flush short terminations with 3.5 mm coaxial connectors from 0.1 GHz to 33 GHz. The pilot laboratory is National Metrology Institute of Japan (NMIJ) and the supporting laboratories are Federal Institute of Metrology (METAS) and National Physical Laboratory (NPL), National Institute of Metrology (NIM), and National Institute of Standards and Technology (NIST). Most of the reported measurement results were generally consistent, while there was a small number of outlying values.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrologia
ISSN
00261394
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
1A
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
309
Strana od-do
1-309
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-105018906931