BEST PRACTICE GUIDE USE OF THERMAL IMAGERS TO PERFORM TRACEABLE NON-CONTACT SCREENING OF HUMAN BODY TEMPERATURE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F21%3AN0000087" target="_blank" >RIV/00177016:_____/21:N0000087 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.bing.com/search?q=BEST+PRACTICE+GUIDE+USE+OF+THERMAL+IMAGERS+TO+PERFORM+TRACEABLE+NON-CONTACT+SCREENING+OF+HUMAN+BODY+TEMPERATURE&cvid=16e4b83a73b4468cb4707e135a411e05&aqs=edge..69i57j69i61.894j0j4&FORM=ANAB01&PC=HCTS" target="_blank" >https://www.bing.com/search?q=BEST+PRACTICE+GUIDE+USE+OF+THERMAL+IMAGERS+TO+PERFORM+TRACEABLE+NON-CONTACT+SCREENING+OF+HUMAN+BODY+TEMPERATURE&cvid=16e4b83a73b4468cb4707e135a411e05&aqs=edge..69i57j69i61.894j0j4&FORM=ANAB01&PC=HCTS</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
BEST PRACTICE GUIDE USE OF THERMAL IMAGERS TO PERFORM TRACEABLE NON-CONTACT SCREENING OF HUMAN BODY TEMPERATURE
Popis výsledku v původním jazyce
This document applies to thermal imagers that are used for the screening of human body temperature. Screening in this case means investigation of human body temperature based on objective measurement. Superficially for rapid measurements usually of a high number of people thermal imaging seems to be an optimal solution. However users shall take great care to develop a measurement protocol that does not jeopardize the reliability and accuracy of the measurement. For thermal imagers measuring human body temperature in the direct (unadjusted) mode with the emissivity set to that of the skin, the temperature range should be at least 30 °C to 40 °C. For thermal imagers measuring human body temperature in the indirect (adjusted) mode (that is, those determining core body temperature using an internal algorithm based on a measurement of skin temperature), the temperature range should cover at least 35 °C to 42 °C.
Název v anglickém jazyce
BEST PRACTICE GUIDE USE OF THERMAL IMAGERS TO PERFORM TRACEABLE NON-CONTACT SCREENING OF HUMAN BODY TEMPERATURE
Popis výsledku anglicky
This document applies to thermal imagers that are used for the screening of human body temperature. Screening in this case means investigation of human body temperature based on objective measurement. Superficially for rapid measurements usually of a high number of people thermal imaging seems to be an optimal solution. However users shall take great care to develop a measurement protocol that does not jeopardize the reliability and accuracy of the measurement. For thermal imagers measuring human body temperature in the direct (unadjusted) mode with the emissivity set to that of the skin, the temperature range should be at least 30 °C to 40 °C. For thermal imagers measuring human body temperature in the indirect (adjusted) mode (that is, those determining core body temperature using an internal algorithm based on a measurement of skin temperature), the temperature range should cover at least 35 °C to 42 °C.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů