Assessment of drug delivery devices working at microflow rates
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F22%3AN0000080" target="_blank" >RIV/00177016:_____/22:N0000080 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1515/bmt-2022-0053" target="_blank" >https://doi.org/10.1515/bmt-2022-0053</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/bmt-2022-0053" target="_blank" >10.1515/bmt-2022-0053</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of drug delivery devices working at microflow rates
Popis výsledku v původním jazyce
Almost every medical department in hospitals around the world uses infusion devices to administer fluids, nutrition, and medications to patients to treat many different diseases and ailments. There have been several reports on adverse incidents caused by medication errors associated with infusion equipment. Such errors can result from malfunction or improper use, or even inaccuracy of the equipment, and can cause harm to patients' health. Depending on the intended use of the equipment, e.g. if it is used for anaesthesia of adults or for medical treatment of premature infants, the accuracy of the equipment may be more or less important. A well-defined metrological infrastructure can help to ensure that infusion devices function properly and are as accurate as needed for their use. However, establishing a metrological infrastructure requires adequate knowledge of the performance of infusion devices in use. This paper presents the results of various tests conducted with two types of devices.
Název v anglickém jazyce
Assessment of drug delivery devices working at microflow rates
Popis výsledku anglicky
Almost every medical department in hospitals around the world uses infusion devices to administer fluids, nutrition, and medications to patients to treat many different diseases and ailments. There have been several reports on adverse incidents caused by medication errors associated with infusion equipment. Such errors can result from malfunction or improper use, or even inaccuracy of the equipment, and can cause harm to patients' health. Depending on the intended use of the equipment, e.g. if it is used for anaesthesia of adults or for medical treatment of premature infants, the accuracy of the equipment may be more or less important. A well-defined metrological infrastructure can help to ensure that infusion devices function properly and are as accurate as needed for their use. However, establishing a metrological infrastructure requires adequate knowledge of the performance of infusion devices in use. This paper presents the results of various tests conducted with two types of devices.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
<a href="/cs/project/8B19002" target="_blank" >8B19002: Metrology for drug delivery</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Engineering / Biomedizinische Technik
ISSN
00135585
e-ISSN
—
Svazek periodika
68
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
14
Strana od-do
51-65
Kód UT WoS článku
000889986200001
EID výsledku v databázi Scopus
2-s2.0-85143083194