Testing micro-flow devices for medical applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F22%3AN0000095" target="_blank" >RIV/00177016:_____/22:N0000095 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Testing micro-flow devices for medical applications
Popis výsledku v původním jazyce
Conference paper at FLOMEKO 2022: Almost every medical department at hospitals all around the world uses infusion devices to administrate fluids, nutrition, and medications to patients for the treatment of numerous different diseases and ailments. Depending on the intended use of the equipment e.g., if it is used for anaesthesia of adults or for medical treatment of premature infants, the accuracy of the equipment can be more or less important. A well-defined metrological infrastructure can help to ensure that infusion devices function properly and are as accurate as needed for their use. However, to establish a metrological infrastructure an appropriated knowledge about infusion devices in use is necessary that enables calibration and testing procedures to be properly defined. This paper summarises the results of various tests conducted with three types of devices – a syringe pump, an infusion device analyser and an insulin pump.
Název v anglickém jazyce
Testing micro-flow devices for medical applications
Popis výsledku anglicky
Conference paper at FLOMEKO 2022: Almost every medical department at hospitals all around the world uses infusion devices to administrate fluids, nutrition, and medications to patients for the treatment of numerous different diseases and ailments. Depending on the intended use of the equipment e.g., if it is used for anaesthesia of adults or for medical treatment of premature infants, the accuracy of the equipment can be more or less important. A well-defined metrological infrastructure can help to ensure that infusion devices function properly and are as accurate as needed for their use. However, to establish a metrological infrastructure an appropriated knowledge about infusion devices in use is necessary that enables calibration and testing procedures to be properly defined. This paper summarises the results of various tests conducted with three types of devices – a syringe pump, an infusion device analyser and an insulin pump.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
<a href="/cs/project/8B19002" target="_blank" >8B19002: Metrology for drug delivery</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů