Improved setup and characterization of cadmium telluride detector for in-beam X-ray spectrometry up to 300 kV at Czech Metrology Institute
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F25%3AN0000107" target="_blank" >RIV/00177016:_____/25:N0000107 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1748-0221/20/02/P02012" target="_blank" >https://doi.org/10.1088/1748-0221/20/02/P02012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/20/02/P02012" target="_blank" >10.1088/1748-0221/20/02/P02012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improved setup and characterization of cadmium telluride detector for in-beam X-ray spectrometry up to 300 kV at Czech Metrology Institute
Popis výsledku v původním jazyce
The paper describes the measurement geometry and summarizes the improvement in the setup and methods used at Czech Metrology Institute for the spectrometry of X-ray beams with cadmium telluride X-123CdTe detector. The front, lateral, and rear shielding of the detector was enlarged and sources of parasitic contribution to the characteristic peaks in the measured spectrum were supressed. Methodology for an accurate positioning of the detector towards the focus point was improved with a tool allowing to visualize projections of two pinholes using a pixel detector. The estimated uncertainty of the alignment was 0.2◦. The tilt of the aperture axis of tungsten collimation disks with 50 μm and 100 μm aperture diameters, which caused distortion of measured spectra, was determined allowing, together with the improved methodology for the detector alignment, to use these disks in the same way as the other collimation disks with larger aperture diameters. As a result, the range of measurable photon flux was increased roughly by a factor of 19. The instrumentation and methods adopted and optimized at CMI allow to perform mobile in-beam X-ray spectrometry up to 300 kV in laboratory and clinical conditions with the range of collimation disks of nominal aperture diameters starting from 50 μm.
Název v anglickém jazyce
Improved setup and characterization of cadmium telluride detector for in-beam X-ray spectrometry up to 300 kV at Czech Metrology Institute
Popis výsledku anglicky
The paper describes the measurement geometry and summarizes the improvement in the setup and methods used at Czech Metrology Institute for the spectrometry of X-ray beams with cadmium telluride X-123CdTe detector. The front, lateral, and rear shielding of the detector was enlarged and sources of parasitic contribution to the characteristic peaks in the measured spectrum were supressed. Methodology for an accurate positioning of the detector towards the focus point was improved with a tool allowing to visualize projections of two pinholes using a pixel detector. The estimated uncertainty of the alignment was 0.2◦. The tilt of the aperture axis of tungsten collimation disks with 50 μm and 100 μm aperture diameters, which caused distortion of measured spectra, was determined allowing, together with the improved methodology for the detector alignment, to use these disks in the same way as the other collimation disks with larger aperture diameters. As a result, the range of measurable photon flux was increased roughly by a factor of 19. The instrumentation and methods adopted and optimized at CMI allow to perform mobile in-beam X-ray spectrometry up to 300 kV in laboratory and clinical conditions with the range of collimation disks of nominal aperture diameters starting from 50 μm.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF INSTRUMENTATION
ISSN
—
e-ISSN
1748-0221
Svazek periodika
20
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
32
Strana od-do
—
Kód UT WoS článku
001434679100001
EID výsledku v databázi Scopus
—