Thermal diffusivity measurements using dual probe Scanning Thermal Microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F25%3AN0000125" target="_blank" >RIV/00177016:_____/25:N0000125 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26110/26:0200082
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1290072925006167" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1290072925006167</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijthermalsci.2025.110293" target="_blank" >10.1016/j.ijthermalsci.2025.110293</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal diffusivity measurements using dual probe Scanning Thermal Microscopy
Popis výsledku v původním jazyce
We present a novel dual probe Scanning Thermal Microscopy setup and methodology for addressing measurements of thermal diffusivity using two microscale thermal probes placed at mutual distance between 1 to , monitoring propagation of heat pulses from one probe to another one through the studied sample. It is shown that even if the measured heat pulses are very weak in this configuration, they can be measured if the heat transfer via air is reduced by measuring in vacuum, radiative heat transfer is reduced by suitable measurement protocol and many pulses are averaged. Resulting signals show the expected dependencies and thermal diffusivity can be evaluated from them with a help of a numerical modeling. Diffusivity measurements are demonstrated on glasses and polymer samples and potential uncertainty sources are identified.
Název v anglickém jazyce
Thermal diffusivity measurements using dual probe Scanning Thermal Microscopy
Popis výsledku anglicky
We present a novel dual probe Scanning Thermal Microscopy setup and methodology for addressing measurements of thermal diffusivity using two microscale thermal probes placed at mutual distance between 1 to , monitoring propagation of heat pulses from one probe to another one through the studied sample. It is shown that even if the measured heat pulses are very weak in this configuration, they can be measured if the heat transfer via air is reduced by measuring in vacuum, radiative heat transfer is reduced by suitable measurement protocol and many pulses are averaged. Resulting signals show the expected dependencies and thermal diffusivity can be evaluated from them with a help of a numerical modeling. Diffusivity measurements are demonstrated on glasses and polymer samples and potential uncertainty sources are identified.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
21100 - Other engineering and technologies
Návaznosti výsledku
Projekt
<a href="/cs/project/GA23-06263S" target="_blank" >GA23-06263S: Termofyzikální charakterizace tenkých vrstev</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Thermal Sciences
ISSN
1290-0729
e-ISSN
1778-4166
Svazek periodika
220
Číslo periodika v rámci svazku
February 2026
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
001575061600001
EID výsledku v databázi Scopus
—