Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00209805%3A_____%2F11%3A%230000188" target="_blank" >RIV/00209805:_____/11:#0000188 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/11:00107038
Výsledek na webu
<a href="http://pubs.rsc.org/en/Content/ArticleLanding/2011/EM/c0em00660b" target="_blank" >http://pubs.rsc.org/en/Content/ArticleLanding/2011/EM/c0em00660b</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c0em00660b" target="_blank" >10.1039/c0em00660b</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene
Popis výsledku v původním jazyce
The main objective of the study was to evaluate the applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide (CP) in the hospital workingenvironment. For this purpose, air contamination of Masaryk Memorial Cancer Institute (Czech Republic) was monitored using the sampling apparatus containing the samplers described above. In addition, the surface contamination was also determined using the wipe sampling technique. During the monitoring, contamination of three different workplaces (storage room, preparation room and outpatient clinic) was studied. Using Strata X solid sorbent tubes, airborne CP was determined in all (n = 5) samples collected at the outpatient clinic over a 5 day monitoring period (concentration range: 0.3-4.3 ng m(-3)). Other samplers (including PTFE filters) did not collect any detectable amount of CP (the limit of detection, LOD < 0.1 ng m(-3)). Negati
Název v anglickém jazyce
Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene
Popis výsledku anglicky
The main objective of the study was to evaluate the applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide (CP) in the hospital workingenvironment. For this purpose, air contamination of Masaryk Memorial Cancer Institute (Czech Republic) was monitored using the sampling apparatus containing the samplers described above. In addition, the surface contamination was also determined using the wipe sampling technique. During the monitoring, contamination of three different workplaces (storage room, preparation room and outpatient clinic) was studied. Using Strata X solid sorbent tubes, airborne CP was determined in all (n = 5) samples collected at the outpatient clinic over a 5 day monitoring period (concentration range: 0.3-4.3 ng m(-3)). Other samplers (including PTFE filters) did not collect any detectable amount of CP (the limit of detection, LOD < 0.1 ng m(-3)). Negati
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FR - Farmakologie a lékárnická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of environmental monitoring
ISSN
1464-0325
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1480-1487
Kód UT WoS článku
000290166800039
EID výsledku v databázi Scopus
—