Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F11%3A00107038" target="_blank" >RIV/00216224:14310/11:00107038 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00209805:_____/11:#0000188
Výsledek na webu
<a href="https://pubs.rsc.org/en/content/articlelanding/2011/EM/c0em00660b#!divAbstract" target="_blank" >https://pubs.rsc.org/en/content/articlelanding/2011/EM/c0em00660b#!divAbstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c0em00660b" target="_blank" >10.1039/c0em00660b</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene
Popis výsledku v původním jazyce
The main objective of the study was to evaluate applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide in the hospital working environment (Masaryk Memorial Cancer Institute, Czech Republic). The study showed that Strata X solid sorbent is an effective tool for the sampling of gaseous cyclophosphamide in the indoor air. Using this sorbent, low levels of airborne cyclophosphamide were determined in the outpatient clinic.
Název v anglickém jazyce
Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene
Popis výsledku anglicky
The main objective of the study was to evaluate applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide in the hospital working environment (Masaryk Memorial Cancer Institute, Czech Republic). The study showed that Strata X solid sorbent is an effective tool for the sampling of gaseous cyclophosphamide in the indoor air. Using this sorbent, low levels of airborne cyclophosphamide were determined in the outpatient clinic.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30304 - Public and environmental health
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0001%2F01%2F01" target="_blank" >ED0001/01/01: CETOCOEN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Environmental Monitoring
ISSN
1464-0325
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1480-1487
Kód UT WoS článku
000290166800039