LightCycler SeptiFast technology in patients with solid malignancies: clinical utility for rapid etiologic diagnosis of sepsis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00209805%3A_____%2F12%3A%230000287" target="_blank" >RIV/00209805:_____/12:#0000287 - isvavai.cz</a>
Výsledek na webu
<a href="http://ccforum.com/content/pdf/cc10595.pdf" target="_blank" >http://ccforum.com/content/pdf/cc10595.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/cc10595" target="_blank" >10.1186/cc10595</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LightCycler SeptiFast technology in patients with solid malignancies: clinical utility for rapid etiologic diagnosis of sepsis
Popis výsledku v původním jazyce
We retrospectively evaluated 54 results of the SeptiFast test from patients with solid malignancy admitted to the ICU between June 2009 and August 2011. Specimens from suspected bloodstream infection were analyzed using LightCycler SeptiFast (Roche Molecular Diagnostics), and evaluated in comparison with blood culture results obtained from blood sampled no longer than 24 hours before or after sampling for SeptiFast. In conclusion, detection of pathogen by the LightCycler SeptiFast system is generally not inferior to the results from blood culture. Th e added value of multiplex DNA amplifi cation-based pathogen detection is the porter test turnaround time and probably the increased true sensitivity of detection of certain pathogens.
Název v anglickém jazyce
LightCycler SeptiFast technology in patients with solid malignancies: clinical utility for rapid etiologic diagnosis of sepsis
Popis výsledku anglicky
We retrospectively evaluated 54 results of the SeptiFast test from patients with solid malignancy admitted to the ICU between June 2009 and August 2011. Specimens from suspected bloodstream infection were analyzed using LightCycler SeptiFast (Roche Molecular Diagnostics), and evaluated in comparison with blood culture results obtained from blood sampled no longer than 24 hours before or after sampling for SeptiFast. In conclusion, detection of pathogen by the LightCycler SeptiFast system is generally not inferior to the results from blood culture. Th e added value of multiplex DNA amplifi cation-based pathogen detection is the porter test turnaround time and probably the increased true sensitivity of detection of certain pathogens.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0101" target="_blank" >ED2.1.00/03.0101: Regionální centrum aplikované molekulární onkologie (RECAMO)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Critical care
ISSN
1364-8535
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
3
Strana od-do
404-406
Kód UT WoS článku
000305393400063
EID výsledku v databázi Scopus
—