LightCycler SeptiFast technology in patients with solid malignancies: clinical utility for rapid etiologic diagnosis of sepsis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F12%3A00062242" target="_blank" >RIV/00216224:14110/12:00062242 - isvavai.cz</a>
Výsledek na webu
<a href="http://ccforum.com/content/16/1/404" target="_blank" >http://ccforum.com/content/16/1/404</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/cc10595" target="_blank" >10.1186/cc10595</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LightCycler SeptiFast technology in patients with solid malignancies: clinical utility for rapid etiologic diagnosis of sepsis
Popis výsledku v původním jazyce
We retrospectively evaluated 54 results of the SeptiFast test from patients with solid malignancy admitted to the ICU between June 2009 and August 2011. Specimens from suspected bloodstream infection were analyzed using LightCycler SeptiFast (Roche Molecular Diagnostics according to the manufacturers instruction and evaluated in comparison with blood culture results obtained from blood sampled no longer than 24 hours before or after sampling for SeptiFast. Blood culturing and identification were performed according to the routine diagnostic procedures. The total number of blood cultures analyzed was 85, and finding a microorganism by either of the two tests was evaluated as positive. Consistently, negative results from SeptiFast and blood culture wereobtained in 21 (39%) cases.
Název v anglickém jazyce
LightCycler SeptiFast technology in patients with solid malignancies: clinical utility for rapid etiologic diagnosis of sepsis
Popis výsledku anglicky
We retrospectively evaluated 54 results of the SeptiFast test from patients with solid malignancy admitted to the ICU between June 2009 and August 2011. Specimens from suspected bloodstream infection were analyzed using LightCycler SeptiFast (Roche Molecular Diagnostics according to the manufacturers instruction and evaluated in comparison with blood culture results obtained from blood sampled no longer than 24 hours before or after sampling for SeptiFast. Blood culturing and identification were performed according to the routine diagnostic procedures. The total number of blood cultures analyzed was 85, and finding a microorganism by either of the two tests was evaluated as positive. Consistently, negative results from SeptiFast and blood culture wereobtained in 21 (39%) cases.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Critical Care
ISSN
1466-609X
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
000305393400063
EID výsledku v databázi Scopus
—