Use of indocyanine green and the HyperEye system for detecting sentinel lymph nodes in breast cancer within a population of European patients: a pilot study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00209805%3A_____%2F16%3AN0000050" target="_blank" >RIV/00209805:_____/16:N0000050 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/16:00092567
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134086/" target="_blank" >https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134086/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12957-016-1060-9" target="_blank" >10.1186/s12957-016-1060-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of indocyanine green and the HyperEye system for detecting sentinel lymph nodes in breast cancer within a population of European patients: a pilot study
Popis výsledku v původním jazyce
Certain studies suggest that using indocyanine green (ICG) could be comparable with using radioisotopes (RI) in detecting sentinel lymph nodes (SLNs) in breast cancer. The objective of our pilot study was to evaluate within a European population of breast cancer patients the detection rate of SLNs using ICG and the HyperEye system and the concordance in SLNs detected using this method and the standard method involving RI and a gamma probe. Ten female patients with early-stage breast cancer indicated for partial mastectomy and SLN biopsy were subjected to standard application of RI. Before surgery, ICG was administered periareolarly in the amount of 1 ml of 0.5% solution. SLNs were first detected perioperatively exclusively using ICG fluorescence and the HyperEye device. Only after removal of all SLNs found in this way was the standard hand-held gamma probe used to detect RI, and any potential additional SLNs not found with ICG were then extirpated. In all 10 cases, at least one SLN was successfully detected using ICG. Nevertheless, in five patients, 1–4 additional SLNs were found using the gamma probe. Complete concordance in detecting SLNs therefore occurred in only one half of the cases. Metastases in SLNs were found in a total of two cases. Had we used only ICG for detection, one of these two cases would have been incorrectly evaluated as N0 (ICG false negativity). The study did not confirm the hypothesis that the use of ICG with the HyperEye system can currently be considered a method fully comparable with using RI and a gamma probe in a population of European patients. Although the detection rate is high, a significantly lower number of SLNs were detected using ICG than using RI (p = 0.03).
Název v anglickém jazyce
Use of indocyanine green and the HyperEye system for detecting sentinel lymph nodes in breast cancer within a population of European patients: a pilot study
Popis výsledku anglicky
Certain studies suggest that using indocyanine green (ICG) could be comparable with using radioisotopes (RI) in detecting sentinel lymph nodes (SLNs) in breast cancer. The objective of our pilot study was to evaluate within a European population of breast cancer patients the detection rate of SLNs using ICG and the HyperEye system and the concordance in SLNs detected using this method and the standard method involving RI and a gamma probe. Ten female patients with early-stage breast cancer indicated for partial mastectomy and SLN biopsy were subjected to standard application of RI. Before surgery, ICG was administered periareolarly in the amount of 1 ml of 0.5% solution. SLNs were first detected perioperatively exclusively using ICG fluorescence and the HyperEye device. Only after removal of all SLNs found in this way was the standard hand-held gamma probe used to detect RI, and any potential additional SLNs not found with ICG were then extirpated. In all 10 cases, at least one SLN was successfully detected using ICG. Nevertheless, in five patients, 1–4 additional SLNs were found using the gamma probe. Complete concordance in detecting SLNs therefore occurred in only one half of the cases. Metastases in SLNs were found in a total of two cases. Had we used only ICG for detection, one of these two cases would have been incorrectly evaluated as N0 (ICG false negativity). The study did not confirm the hypothesis that the use of ICG with the HyperEye system can currently be considered a method fully comparable with using RI and a gamma probe in a population of European patients. Although the detection rate is high, a significantly lower number of SLNs were detected using ICG than using RI (p = 0.03).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1413" target="_blank" >LO1413: RECAMO2020</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
World Journal of Surgical Oncology
ISSN
1477-7819
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
299-304
Kód UT WoS článku
000391145500001
EID výsledku v databázi Scopus
—