High-sensitivity troponin T as a marker of myocardial injury after radiofrequency catheter ablation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F11%3A11275" target="_blank" >RIV/00216208:11110/11:11275 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/11:00002536 RIV/00216208:11150/11:10107590 RIV/00179906:_____/11:10107590 RIV/00064190:_____/11:#0000236
Výsledek na webu
<a href="http://dx.doi.org/10.1258/acb.2010.009280" target="_blank" >http://dx.doi.org/10.1258/acb.2010.009280</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-sensitivity troponin T as a marker of myocardial injury after radiofrequency catheter ablation
Popis výsledku v původním jazyce
Background: The aim of our study was to monitor radiofrequency catheter ablation-induced myocardial damage by measuring high-sensitivity cardiac troponin T (hs-cTnT). Methods: Serum concentrations of hs-cTnT (Elecsys 2010 system, Roche) were measured in73 healthy blood donors and serially in 27 patients who had samples taken both before and 24 h after radiofrequency ablation (RFA) for atrioventricular nodal re-entry tachycardia (AVNRT), atrial fibrillation (AF) or right atrial flutter (AFL). Results: Significant increases of hs-cTnT were seen in patients after RFA (AVNRT: P = 0.0115, AF: P = 0.0011, AFL: P = 0.0009). Postprocedural serum hs-cTnT correlated with the number of radiofrequency applications and with the duration of RFA procedure. Spearman's coefficient of rank correlation (r) were as follows: hs-cTnT versus RFA duration: r = 0.771 (P < 0.001); hs-cTnT versus number of pulses: r = 0.708 (P < 0.001). Patients with the diagnosis of AVNRT had lower serum hs-cTnT concentration
Název v anglickém jazyce
High-sensitivity troponin T as a marker of myocardial injury after radiofrequency catheter ablation
Popis výsledku anglicky
Background: The aim of our study was to monitor radiofrequency catheter ablation-induced myocardial damage by measuring high-sensitivity cardiac troponin T (hs-cTnT). Methods: Serum concentrations of hs-cTnT (Elecsys 2010 system, Roche) were measured in73 healthy blood donors and serially in 27 patients who had samples taken both before and 24 h after radiofrequency ablation (RFA) for atrioventricular nodal re-entry tachycardia (AVNRT), atrial fibrillation (AF) or right atrial flutter (AFL). Results: Significant increases of hs-cTnT were seen in patients after RFA (AVNRT: P = 0.0115, AF: P = 0.0011, AFL: P = 0.0009). Postprocedural serum hs-cTnT correlated with the number of radiofrequency applications and with the duration of RFA procedure. Spearman's coefficient of rank correlation (r) were as follows: hs-cTnT versus RFA duration: r = 0.771 (P < 0.001); hs-cTnT versus number of pulses: r = 0.708 (P < 0.001). Patients with the diagnosis of AVNRT had lower serum hs-cTnT concentration
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Annals of Clinical Biochemistry
ISSN
0004-5632
e-ISSN
—
Svazek periodika
48
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
3
Strana od-do
38-40
Kód UT WoS článku
000290425000006
EID výsledku v databázi Scopus
—