Modeling of load transmission and distribution of deformation energy before and after healing of basal dental implants in the human mandible
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F11%3A11320" target="_blank" >RIV/00216208:11110/11:11320 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/11:00171687 RIV/00064165:_____/11:11320
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modeling of load transmission and distribution of deformation energy before and after healing of basal dental implants in the human mandible
Popis výsledku v původním jazyce
The purpose of this study was to present the amount and distribution of pressure, stress, and deformation energy when basal implants in the mandible are restored with a bridge which is loaded at two different stages of bone healing. The model geometry and material properties of the mandible were gained from CT scans of a human mandible. The material model used in this study defined bone as an inhomogeneous, linear elastic isotropic material. The masseter and temporal muscles were considered as rigid connections between the bones in typical positions and directions. The rotation axis was simulated in the temporomandibular joint. The loading force of 450 N was assumed to be in the middle between the left molar and left canine implant. In freshly operatedbone, the total deformation energy is 30% higher than in healed bone, due to the defined energy absorbing soft bone areas. Approximately 90% of the deformation energy is absorbed by the bone, regardless of the healing state of the bone.
Název v anglickém jazyce
Modeling of load transmission and distribution of deformation energy before and after healing of basal dental implants in the human mandible
Popis výsledku anglicky
The purpose of this study was to present the amount and distribution of pressure, stress, and deformation energy when basal implants in the mandible are restored with a bridge which is loaded at two different stages of bone healing. The model geometry and material properties of the mandible were gained from CT scans of a human mandible. The material model used in this study defined bone as an inhomogeneous, linear elastic isotropic material. The masseter and temporal muscles were considered as rigid connections between the bones in typical positions and directions. The rotation axis was simulated in the temporomandibular joint. The loading force of 450 N was assumed to be in the middle between the left molar and left canine implant. In freshly operatedbone, the total deformation energy is 30% higher than in healed bone, due to the defined energy absorbing soft bone areas. Approximately 90% of the deformation energy is absorbed by the bone, regardless of the healing state of the bone.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedizinische Technik
ISSN
0013-5585
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
53-58
Kód UT WoS článku
000295448000007