Quality Assessment of Fetal Nuchal Translucency Measurements in the First Trimester of Pregnancy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F11%3A8841" target="_blank" >RIV/00216208:11110/11:8841 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985807:_____/11:00373481
Výsledek na webu
<a href="http://www.ejbi.eu/images/2011-1/Hynek_en.pdf" target="_blank" >http://www.ejbi.eu/images/2011-1/Hynek_en.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quality Assessment of Fetal Nuchal Translucency Measurements in the First Trimester of Pregnancy
Popis výsledku v původním jazyce
Objectives: To evaluate and compare the performance of various quality control methods for nuchal translucency (NT) measurements. Methods: Fetal NT measurements performed over a oneyear period in a single center were used for the study. The retrospectivequality review methods proposed by the Fetal Medicine Foundation (FMF) and the Woman and Infants Hospital of Rhode Island (WIHRI) were assessed in the whole data set and in sonographer-specific distributions. Further prospective statistic process control (SPC) methods were applied (Shewhart x and s charts, exponentially weighted moving average (EWMA) and cumulative sum (CUSUM) charts). Results: Three thousand five hundred and seventy eight NT measurements obtained by seven sonographers were eligible for designed analysis. In the assessment of the sonographer-specific NT distributions three of them did not meet due to the underestimation the FMF and one the WIHRI criteria. Using SPC methods, three sonographers presented unsatisfactory p
Název v anglickém jazyce
Quality Assessment of Fetal Nuchal Translucency Measurements in the First Trimester of Pregnancy
Popis výsledku anglicky
Objectives: To evaluate and compare the performance of various quality control methods for nuchal translucency (NT) measurements. Methods: Fetal NT measurements performed over a oneyear period in a single center were used for the study. The retrospectivequality review methods proposed by the Fetal Medicine Foundation (FMF) and the Woman and Infants Hospital of Rhode Island (WIHRI) were assessed in the whole data set and in sonographer-specific distributions. Further prospective statistic process control (SPC) methods were applied (Shewhart x and s charts, exponentially weighted moving average (EWMA) and cumulative sum (CUSUM) charts). Results: Three thousand five hundred and seventy eight NT measurements obtained by seven sonographers were eligible for designed analysis. In the assessment of the sonographer-specific NT distributions three of them did not meet due to the underestimation the FMF and one the WIHRI criteria. Using SPC methods, three sonographers presented unsatisfactory p
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FM - Hygiena
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal for Biomedical Informatics
ISSN
1801-5603
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
22-32
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—