Real-time Quality Control of Nuchal Translucency Measurements Using the Exponentially Weighted Moving Average Chart
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985807%3A_____%2F21%3A00534859" target="_blank" >RIV/67985807:_____/21:00534859 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064190:_____/21:N0000108
Výsledek na webu
<a href="http://hdl.handle.net/11104/0313018" target="_blank" >http://hdl.handle.net/11104/0313018</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.tjog.2020.11.012" target="_blank" >10.1016/j.tjog.2020.11.012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-time Quality Control of Nuchal Translucency Measurements Using the Exponentially Weighted Moving Average Chart
Popis výsledku v původním jazyce
OBJECTIVE: The establishment of ongoing audits for first-trimester nuchal translucency (NT) measurements is of paramount importance. The exponentially weighted moving average (EWMA) chart has been published as an efficient tool for NT quality control with the advantages of being suitable for real-time long-term monitoring. This study aimed to assess the efficacy of real-time NT quality control using EWMA charts. MATERIALS AND METHODS: This was an ongoing prospective study conducted from January 2011 to December 2017 at the Centre for Fetal Medicine Gennet in Prague. The quality of NT measurements was assessed using the NT retrospective distribution parameters and EWMA charts, and the results were presented to the sonographers during collective meetings. RESULTS: Overall, 28,928 NT measurements obtained from six sonographers were eligible for the study. Looking at individual EWMA charts, we observed four main outcomes. First, there was a clear improvement in the performance of sonographers with initially poor performances. Second, the performance of sonographers with an initially satisfactory quality was maintained. Third, there was an observed deterioration of the performance without the audits. Last, the sonographers appreciated an unequivocal and straightforward graphical presentation of EWMA curves. CONCLUSION: EWMA proved to be an efficient and suitable tool for real-time monitoring of NT quality and led to an overall improvement of the sonographers’ performance.
Název v anglickém jazyce
Real-time Quality Control of Nuchal Translucency Measurements Using the Exponentially Weighted Moving Average Chart
Popis výsledku anglicky
OBJECTIVE: The establishment of ongoing audits for first-trimester nuchal translucency (NT) measurements is of paramount importance. The exponentially weighted moving average (EWMA) chart has been published as an efficient tool for NT quality control with the advantages of being suitable for real-time long-term monitoring. This study aimed to assess the efficacy of real-time NT quality control using EWMA charts. MATERIALS AND METHODS: This was an ongoing prospective study conducted from January 2011 to December 2017 at the Centre for Fetal Medicine Gennet in Prague. The quality of NT measurements was assessed using the NT retrospective distribution parameters and EWMA charts, and the results were presented to the sonographers during collective meetings. RESULTS: Overall, 28,928 NT measurements obtained from six sonographers were eligible for the study. Looking at individual EWMA charts, we observed four main outcomes. First, there was a clear improvement in the performance of sonographers with initially poor performances. Second, the performance of sonographers with an initially satisfactory quality was maintained. Third, there was an observed deterioration of the performance without the audits. Last, the sonographers appreciated an unequivocal and straightforward graphical presentation of EWMA curves. CONCLUSION: EWMA proved to be an efficient and suitable tool for real-time monitoring of NT quality and led to an overall improvement of the sonographers’ performance.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10103 - Statistics and probability
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Taiwanese Journal of Obstetrics and Gynecology
ISSN
1028-4559
e-ISSN
—
Svazek periodika
60
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
HK - Hongkong
Počet stran výsledku
6
Strana od-do
84-89
Kód UT WoS článku
000631884400016
EID výsledku v databázi Scopus
2-s2.0-85096845357