Sub-Volume Averaging of Repetitive Structural Features in Angularly Filtered Electron Tomographic Reconstructions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10285506" target="_blank" >RIV/00216208:11110/14:10285506 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14330/14:00080247
Výsledek na webu
<a href="http://fb.cuni.cz/file/5748/fb2014a0035.pdf" target="_blank" >http://fb.cuni.cz/file/5748/fb2014a0035.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sub-Volume Averaging of Repetitive Structural Features in Angularly Filtered Electron Tomographic Reconstructions
Popis výsledku v původním jazyce
Electron tomographic reconstructions suffer from a number of artefacts arising from effects accompanying the processes of acquisition of a set of tilted projections of the specimen in a transmission electron microscope and from its subsequent computational handling. The most pronounced artefacts usually come from imprecise projection alignment, distortion of specimens during tomogram acquisition and from the presence of a region of missing data in the Fourier space, the "missing wedge". The ray artefacts caused by the presence of the missing wedge can be attenuated by the angular image filter, which attenuates the transition between the data and the missing wedge regions. In this work, we present an analysis of the influence of angular filtering on theresolution of averaged repetitive structural motives extracted from three-dimensional reconstructions of tomograms acquired in the single-axis tilting geometry.
Název v anglickém jazyce
Sub-Volume Averaging of Repetitive Structural Features in Angularly Filtered Electron Tomographic Reconstructions
Popis výsledku anglicky
Electron tomographic reconstructions suffer from a number of artefacts arising from effects accompanying the processes of acquisition of a set of tilted projections of the specimen in a transmission electron microscope and from its subsequent computational handling. The most pronounced artefacts usually come from imprecise projection alignment, distortion of specimens during tomogram acquisition and from the presence of a region of missing data in the Fourier space, the "missing wedge". The ray artefacts caused by the presence of the missing wedge can be attenuated by the angular image filter, which attenuates the transition between the data and the missing wedge regions. In this work, we present an analysis of the influence of angular filtering on theresolution of averaged repetitive structural motives extracted from three-dimensional reconstructions of tomograms acquired in the single-axis tilting geometry.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EA - Morfologické obory a cytologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Folia Biologica
ISSN
0015-5500
e-ISSN
—
Svazek periodika
60
Číslo periodika v rámci svazku
S1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
66-70
Kód UT WoS článku
000343275800011