Er:YAG laser delivery systems and sonic-activated bulk composite restoration: sculpturing and microleakage evaluation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10292806" target="_blank" >RIV/00216208:11110/14:10292806 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/14:00219648 RIV/00216208:11130/14:10292806 RIV/00064203:_____/14:10292806
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.2036771" target="_blank" >http://dx.doi.org/10.1117/12.2036771</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2036771" target="_blank" >10.1117/12.2036771</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Er:YAG laser delivery systems and sonic-activated bulk composite restoration: sculpturing and microleakage evaluation
Popis výsledku v původním jazyce
The comparison of tissue quality and its restoration after contact, non-contact, and non-contact scanned Er:YAG (2940 nm) laser radiation ablation was evaluated. Laser setting for contact ablation was 250 mJ/pulse, pulse repetition rate 15 Hz, average power 3.75 W. For non-contact ablation these values were 600 mJ/pulse, 6 Hz, 3.6 W. All cavities were filled by sonic activated composite resin. Microleakage was assessed quantitatively by the degree of dye penetration. Cavity prepared by contact mode withsonic-activated composite filling protects microleakage formation.
Název v anglickém jazyce
Er:YAG laser delivery systems and sonic-activated bulk composite restoration: sculpturing and microleakage evaluation
Popis výsledku anglicky
The comparison of tissue quality and its restoration after contact, non-contact, and non-contact scanned Er:YAG (2940 nm) laser radiation ablation was evaluated. Laser setting for contact ablation was 250 mJ/pulse, pulse repetition rate 15 Hz, average power 3.75 W. For non-contact ablation these values were 600 mJ/pulse, 6 Hz, 3.6 W. All cavities were filled by sonic activated composite resin. Microleakage was assessed quantitatively by the degree of dye penetration. Cavity prepared by contact mode withsonic-activated composite filling protects microleakage formation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE - The International Society for Optical Engineering
ISBN
978-0-8194-9842-7
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
SPIE-INT SOC OPTICAL ENGINEERING
Místo vydání
BELLINGHAM
Místo konání akce
San Francisco
Datum konání akce
2. 2. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000334341900008