Er: YAG laser radiation: contact versus non-contact enamel ablation and sonic-activated bulk composite placement: microleakage evaluation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F15%3A10294560" target="_blank" >RIV/00216208:11130/15:10294560 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/15:00235355 RIV/00064203:_____/15:10294560 RIV/00064165:_____/15:10294560
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1054-660X/25/2/025604" target="_blank" >http://dx.doi.org/10.1088/1054-660X/25/2/025604</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1054-660X/25/2/025604" target="_blank" >10.1088/1054-660X/25/2/025604</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Er: YAG laser radiation: contact versus non-contact enamel ablation and sonic-activated bulk composite placement: microleakage evaluation
Popis výsledku v původním jazyce
Our study aims to analyze the bond after the Er: YAG laser-radiation-prepared cavity was filled with a new kind of bulk-filled composite material. The laser radiation acted in a contact and non-contact mode. The setting for contact ablation was as follows: energy 250 mJ/pulse with a pulse repetition rate 15 Hz, giving an average power of 3.75 W. For non-contact ablation these values were 600 mJ/pulse, 6 Hz, and 3.6 W. Scanning ablation was provided in non-contact mode (1440 pulses/cavity) and the parameters were: energy 300 mJ/pulse, repetition rate 1 Hz, and mean power 0.3 W. Three types of laser cavities were filled with sonic activated composite resin. Four longitudinal sections were prepared after immersion in 5% methylene blue for 24 h. Microleakage was assessed quantitatively by the degree of dye penetration; the data were analyzed by the Fisher exact test with the level of significance set at p < 0.05. Contact and non-contact laser treatments prepared similar cavities (5167.31 v
Název v anglickém jazyce
Er: YAG laser radiation: contact versus non-contact enamel ablation and sonic-activated bulk composite placement: microleakage evaluation
Popis výsledku anglicky
Our study aims to analyze the bond after the Er: YAG laser-radiation-prepared cavity was filled with a new kind of bulk-filled composite material. The laser radiation acted in a contact and non-contact mode. The setting for contact ablation was as follows: energy 250 mJ/pulse with a pulse repetition rate 15 Hz, giving an average power of 3.75 W. For non-contact ablation these values were 600 mJ/pulse, 6 Hz, and 3.6 W. Scanning ablation was provided in non-contact mode (1440 pulses/cavity) and the parameters were: energy 300 mJ/pulse, repetition rate 1 Hz, and mean power 0.3 W. Three types of laser cavities were filled with sonic activated composite resin. Four longitudinal sections were prepared after immersion in 5% methylene blue for 24 h. Microleakage was assessed quantitatively by the degree of dye penetration; the data were analyzed by the Fisher exact test with the level of significance set at p < 0.05. Contact and non-contact laser treatments prepared similar cavities (5167.31 v
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13351" target="_blank" >NT13351: 3- D rekonstrukce tvrdých a měkkých zubních tkání u hendikepovaných pacientů - stabilita léčby</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Laser Physics
ISSN
1054-660X
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
RU - Ruská federace
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
000348143000016
EID výsledku v databázi Scopus
2-s2.0-84921473968