Quantitation of plasmatic lysosphingomyelin and lysosphingomyelin-509 for differential screening of Niemann-Pick A/B and C diseases
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10362278" target="_blank" >RIV/00216208:11110/17:10362278 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/17:10362278
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ab.2017.02.019" target="_blank" >http://dx.doi.org/10.1016/j.ab.2017.02.019</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ab.2017.02.019" target="_blank" >10.1016/j.ab.2017.02.019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantitation of plasmatic lysosphingomyelin and lysosphingomyelin-509 for differential screening of Niemann-Pick A/B and C diseases
Popis výsledku v původním jazyce
Acid sphingomyelinase deficiency (ASMd, Niemann-Pick disease A/B) and Niemann-Pick type C disease (NPC) share core clinical symptoms. Initial diagnostic discrimination of these two rare lysosomal storage diseases is thus difficult. As sphingomyelin accumulates in ASMd as well as NPC, lysosphingomyelin (sphingosylphosphorylcholine) and its m/z 509 analog were suggested as biomarkers for both diseases. Herein we present results of simultaneous LC-ESI-MS/MS measurements of lysosphingomyelin and lysosphingomyelin 509 in plasma and dried blood spots (DBS) collected from ASMd and NPC patients and suggest that the plasma but not DBS levels of the two analytes allow differential biochemical screening of ASMd and NPC.
Název v anglickém jazyce
Quantitation of plasmatic lysosphingomyelin and lysosphingomyelin-509 for differential screening of Niemann-Pick A/B and C diseases
Popis výsledku anglicky
Acid sphingomyelinase deficiency (ASMd, Niemann-Pick disease A/B) and Niemann-Pick type C disease (NPC) share core clinical symptoms. Initial diagnostic discrimination of these two rare lysosomal storage diseases is thus difficult. As sphingomyelin accumulates in ASMd as well as NPC, lysosphingomyelin (sphingosylphosphorylcholine) and its m/z 509 analog were suggested as biomarkers for both diseases. Herein we present results of simultaneous LC-ESI-MS/MS measurements of lysosphingomyelin and lysosphingomyelin 509 in plasma and dried blood spots (DBS) collected from ASMd and NPC patients and suggest that the plasma but not DBS levels of the two analytes allow differential biochemical screening of ASMd and NPC.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10608 - Biochemistry and molecular biology
Návaznosti výsledku
Projekt
<a href="/cs/project/NV16-33923A" target="_blank" >NV16-33923A: Nový test pro klasickou a variantní Niemann-Pickovu chorobu typu C. Zjištění patogenity častých alel spojovaných s pozdními formami NPC.</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Biochemistry
ISSN
0003-2697
e-ISSN
—
Svazek periodika
525
Číslo periodika v rámci svazku
May
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
73-77
Kód UT WoS článku
000398878700011
EID výsledku v databázi Scopus
2-s2.0-85014863349