Vše

Co hledáte?

Vše
Projekty
Výsledky výzkumu
Subjekty

Rychlé hledání

  • Projekty podpořené TA ČR
  • Významné projekty
  • Projekty s nejvyšší státní podporou
  • Aktuálně běžící projekty

Chytré vyhledávání

  • Takto najdu konkrétní +slovo
  • Takto z výsledků -slovo zcela vynechám
  • “Takto můžu najít celou frázi”

The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F18%3A10382011" target="_blank" >RIV/00216208:11110/18:10382011 - isvavai.cz</a>

  • Nalezeny alternativní kódy

    RIV/61388955:_____/18:00492518 RIV/00216208:11510/18:10382011

  • Výsledek na webu

    <a href="https://doi.org/10.1007/s00706-018-2236-5" target="_blank" >https://doi.org/10.1007/s00706-018-2236-5</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00706-018-2236-5" target="_blank" >10.1007/s00706-018-2236-5</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1

  • Popis výsledku v původním jazyce

    This article deals with assessment of accuracy of the widely used glucose sensors MMT-7002 (Medtronic, USA), for continuous monitoring of glucose levels. The samples were gained from a 35-year-old sportswoman with diagnosed DM type 1. The sampling was carried out by her common daily as well as extreme physical and sport activities. The evaluated data were collected during 45 months, 56 sensors were used and 603 calibrations were carried out. The tested glucose sensor operates on the principle of a needle sensor, which electrochemically evaluates the reaction products catalyzed by glucose oxidase. Accuracy was evaluated by Clarke error grid analysis and the results were compared with the accuracy given by the sensor manufacturer. The measurements carried out by the tested sensor in the range of the normal glucose levels, realized under usual life conditions and by sport activities were even more accurate than those given by the manufacturer. However, in the regions of hypoglycemia or hyperglycemia, the number of errors was higher than specified by the manufacturer. The continuous glucose monitoring proved to be sufficiently accurate for prevention of acute complications in patients with DM type 1 during their common as well as extreme sport and physical activities.

  • Název v anglickém jazyce

    The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1

  • Popis výsledku anglicky

    This article deals with assessment of accuracy of the widely used glucose sensors MMT-7002 (Medtronic, USA), for continuous monitoring of glucose levels. The samples were gained from a 35-year-old sportswoman with diagnosed DM type 1. The sampling was carried out by her common daily as well as extreme physical and sport activities. The evaluated data were collected during 45 months, 56 sensors were used and 603 calibrations were carried out. The tested glucose sensor operates on the principle of a needle sensor, which electrochemically evaluates the reaction products catalyzed by glucose oxidase. Accuracy was evaluated by Clarke error grid analysis and the results were compared with the accuracy given by the sensor manufacturer. The measurements carried out by the tested sensor in the range of the normal glucose levels, realized under usual life conditions and by sport activities were even more accurate than those given by the manufacturer. However, in the regions of hypoglycemia or hyperglycemia, the number of errors was higher than specified by the manufacturer. The continuous glucose monitoring proved to be sufficiently accurate for prevention of acute complications in patients with DM type 1 during their common as well as extreme sport and physical activities.

Klasifikace

  • Druh

    J<sub>imp</sub> - Článek v periodiku v databázi Web of Science

  • CEP obor

  • OECD FORD obor

    10608 - Biochemistry and molecular biology

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>

  • Návaznosti

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Ostatní

  • Rok uplatnění

    2018

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Monatshefte für Chemie - Chemical Monthly

  • ISSN

    0026-9247

  • e-ISSN

  • Svazek periodika

    149

  • Číslo periodika v rámci svazku

    9

  • Stát vydavatele periodika

    AT - Rakouská republika

  • Počet stran výsledku

    11

  • Strana od-do

    1659-1669

  • Kód UT WoS článku

    000442501400023

  • EID výsledku v databázi Scopus

    2-s2.0-85051676865