The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F18%3A10382011" target="_blank" >RIV/00216208:11110/18:10382011 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/18:00492518 RIV/00216208:11510/18:10382011
Výsledek na webu
<a href="https://doi.org/10.1007/s00706-018-2236-5" target="_blank" >https://doi.org/10.1007/s00706-018-2236-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-018-2236-5" target="_blank" >10.1007/s00706-018-2236-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
Popis výsledku v původním jazyce
This article deals with assessment of accuracy of the widely used glucose sensors MMT-7002 (Medtronic, USA), for continuous monitoring of glucose levels. The samples were gained from a 35-year-old sportswoman with diagnosed DM type 1. The sampling was carried out by her common daily as well as extreme physical and sport activities. The evaluated data were collected during 45 months, 56 sensors were used and 603 calibrations were carried out. The tested glucose sensor operates on the principle of a needle sensor, which electrochemically evaluates the reaction products catalyzed by glucose oxidase. Accuracy was evaluated by Clarke error grid analysis and the results were compared with the accuracy given by the sensor manufacturer. The measurements carried out by the tested sensor in the range of the normal glucose levels, realized under usual life conditions and by sport activities were even more accurate than those given by the manufacturer. However, in the regions of hypoglycemia or hyperglycemia, the number of errors was higher than specified by the manufacturer. The continuous glucose monitoring proved to be sufficiently accurate for prevention of acute complications in patients with DM type 1 during their common as well as extreme sport and physical activities.
Název v anglickém jazyce
The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
Popis výsledku anglicky
This article deals with assessment of accuracy of the widely used glucose sensors MMT-7002 (Medtronic, USA), for continuous monitoring of glucose levels. The samples were gained from a 35-year-old sportswoman with diagnosed DM type 1. The sampling was carried out by her common daily as well as extreme physical and sport activities. The evaluated data were collected during 45 months, 56 sensors were used and 603 calibrations were carried out. The tested glucose sensor operates on the principle of a needle sensor, which electrochemically evaluates the reaction products catalyzed by glucose oxidase. Accuracy was evaluated by Clarke error grid analysis and the results were compared with the accuracy given by the sensor manufacturer. The measurements carried out by the tested sensor in the range of the normal glucose levels, realized under usual life conditions and by sport activities were even more accurate than those given by the manufacturer. However, in the regions of hypoglycemia or hyperglycemia, the number of errors was higher than specified by the manufacturer. The continuous glucose monitoring proved to be sufficiently accurate for prevention of acute complications in patients with DM type 1 during their common as well as extreme sport and physical activities.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10608 - Biochemistry and molecular biology
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie - Chemical Monthly
ISSN
0026-9247
e-ISSN
—
Svazek periodika
149
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
11
Strana od-do
1659-1669
Kód UT WoS článku
000442501400023
EID výsledku v databázi Scopus
2-s2.0-85051676865