Comparison of Different Thawing Protocols in Human Cryopreserved Venous Grafts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10403210" target="_blank" >RIV/00216208:11110/20:10403210 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/20:10403210 RIV/00216208:11310/20:10403210 RIV/00179906:_____/20:10403210 RIV/00023001:_____/20:00079473 RIV/00064165:_____/20:10403210
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=tidXxZ6PSJ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=tidXxZ6PSJ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.avsg.2019.11.026" target="_blank" >10.1016/j.avsg.2019.11.026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Different Thawing Protocols in Human Cryopreserved Venous Grafts
Popis výsledku v původním jazyce
BACKGROUND: The aim of our study was to assess the impact of different thawing protocols on morphological changes arising in cryopreserved human saphenous vein grafts. METHODS: The study was performed in 12 saphenous vein grafts harvested in brain death donors. Storage in the vapor phase of liquid nitrogen for 3 or 5 years followed. Two thawing protocols were tested: slow thawing in a refrigerator at temperature +4°C for 2 hr and rapid thawing-in a water bath at +37°C. Grafts were processed for scanning electron microscopy. Comparisons of continuous parameters under study between experimental groups were performed using the t-test (age, cold ischemia time, exposure to cryoprotectant, time of storage, total thawing time, mean thawing rate, morphology scoring of thawed HSVG) and the median test (HSVG length). Categorical parameters (sex and blood group) were formally tested using the chi-square test. RESULTS: All samples were evaluated according to morphological changes and scored in terms of morphologically intact endothelium, confluent endothelium with structural inhomogeneity, disruption of the intercellular contacts, separation of the endothelial cells, complete loss of the endothelium, and damage of the subendothelial layers. There is no statistically significant difference between the sample sets at the significance level of 0.05. There was no association with donors' age, sex, and time of storage. CONCLUSIONS: Human cryopreserved saphenous vein grafts in our experimental work showed no difference in terms of structural deterioration of the endothelial surface and basal membrane depending on different thawing protocols used.
Název v anglickém jazyce
Comparison of Different Thawing Protocols in Human Cryopreserved Venous Grafts
Popis výsledku anglicky
BACKGROUND: The aim of our study was to assess the impact of different thawing protocols on morphological changes arising in cryopreserved human saphenous vein grafts. METHODS: The study was performed in 12 saphenous vein grafts harvested in brain death donors. Storage in the vapor phase of liquid nitrogen for 3 or 5 years followed. Two thawing protocols were tested: slow thawing in a refrigerator at temperature +4°C for 2 hr and rapid thawing-in a water bath at +37°C. Grafts were processed for scanning electron microscopy. Comparisons of continuous parameters under study between experimental groups were performed using the t-test (age, cold ischemia time, exposure to cryoprotectant, time of storage, total thawing time, mean thawing rate, morphology scoring of thawed HSVG) and the median test (HSVG length). Categorical parameters (sex and blood group) were formally tested using the chi-square test. RESULTS: All samples were evaluated according to morphological changes and scored in terms of morphologically intact endothelium, confluent endothelium with structural inhomogeneity, disruption of the intercellular contacts, separation of the endothelial cells, complete loss of the endothelium, and damage of the subendothelial layers. There is no statistically significant difference between the sample sets at the significance level of 0.05. There was no association with donors' age, sex, and time of storage. CONCLUSIONS: Human cryopreserved saphenous vein grafts in our experimental work showed no difference in terms of structural deterioration of the endothelial surface and basal membrane depending on different thawing protocols used.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2015062" target="_blank" >LM2015062: Národní infrastruktura pro biologické a medicínské zobrazování</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Annals of Vascular Surgery
ISSN
0890-5096
e-ISSN
—
Svazek periodika
64
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
347-354
Kód UT WoS článku
000521506600046
EID výsledku v databázi Scopus
2-s2.0-85076854233