The repeatability of the instrumented timed Up & Go test: The performance of older adults and parkinson's disease patients under different conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10405728" target="_blank" >RIV/00216208:11110/20:10405728 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/20:10405728 RIV/00216208:11310/20:10405728 RIV/68407700:21460/20:00336091
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=KgezGNc0i0" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=KgezGNc0i0</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bbe.2019.12.001" target="_blank" >10.1016/j.bbe.2019.12.001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The repeatability of the instrumented timed Up & Go test: The performance of older adults and parkinson's disease patients under different conditions
Popis výsledku v původním jazyce
The Timed Up & Go (TUG) test is a simple test for gait and balance that requires no special equipment and can be part of a routine clinical examination. Combined with the development of motion capture technologies, the possibilities of assessing individual TUG sub-components (i.e. sit-to-stand, gait, turn, turn-to-sit) are increasing. The clinical evaluation of an instrumented TUG requires reliable values. We analysed the intra-session repeatability of the iTUG sit-to-stand, gait and turn parameters in three conditions: (1) single, (2) cognitive dual-tasks, and (3) manual dual-tasks in older adults and Parkinson's disease (PD) patients. The repeatability coefficient (RC) was calculated for each of the 18 parameters. The repeatability varied across subject groups, the performed tasks, and the TUG subcomponent. The gait subcomponent had 6 non-repeatable spatio-temporal parameters and 2 non-repeatable parameters for the arm swing. The parameters of the turn subcomponent can be considered as non-repeatable in both groups under the manual dual-task condition and in HC under the single-task condition. When comparing PD to HC, the repeatability of the majority of the single-task parameters was higher in PD whereas lower under dual-tasks. In PD, the major part of gait parameters had a higher repeatability under single-tasks than dual-tasks. In contrast, HC exhibited better repeatability of dual-tasks than single-tasks. Repeatability can be used to assist researchers and clinicians to select adequate parameters with respect to the purpose of motion assessment.
Název v anglickém jazyce
The repeatability of the instrumented timed Up & Go test: The performance of older adults and parkinson's disease patients under different conditions
Popis výsledku anglicky
The Timed Up & Go (TUG) test is a simple test for gait and balance that requires no special equipment and can be part of a routine clinical examination. Combined with the development of motion capture technologies, the possibilities of assessing individual TUG sub-components (i.e. sit-to-stand, gait, turn, turn-to-sit) are increasing. The clinical evaluation of an instrumented TUG requires reliable values. We analysed the intra-session repeatability of the iTUG sit-to-stand, gait and turn parameters in three conditions: (1) single, (2) cognitive dual-tasks, and (3) manual dual-tasks in older adults and Parkinson's disease (PD) patients. The repeatability coefficient (RC) was calculated for each of the 18 parameters. The repeatability varied across subject groups, the performed tasks, and the TUG subcomponent. The gait subcomponent had 6 non-repeatable spatio-temporal parameters and 2 non-repeatable parameters for the arm swing. The parameters of the turn subcomponent can be considered as non-repeatable in both groups under the manual dual-task condition and in HC under the single-task condition. When comparing PD to HC, the repeatability of the majority of the single-task parameters was higher in PD whereas lower under dual-tasks. In PD, the major part of gait parameters had a higher repeatability under single-tasks than dual-tasks. In contrast, HC exhibited better repeatability of dual-tasks than single-tasks. Repeatability can be used to assist researchers and clinicians to select adequate parameters with respect to the purpose of motion assessment.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biocybernetics and Biomedical Engineering
ISSN
0208-5216
e-ISSN
—
Svazek periodika
40
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
15
Strana od-do
363-377
Kód UT WoS článku
000528800500028
EID výsledku v databázi Scopus
2-s2.0-85077916021