Video Laryngoscopic Intubation Using the King Vision (TM) Laryngoscope in a Simulated Cervical Spine Trauma: A Comparison Between Non-Channeled and Channeled Disposable Blades
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10410761" target="_blank" >RIV/00216208:11110/20:10410761 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61383082:_____/20:00000969 RIV/00216224:14110/20:00116241 RIV/00216208:11130/20:10410761 RIV/00064203:_____/20:10410761 RIV/00064165:_____/20:10410761
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=FQmHEV.6SN" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=FQmHEV.6SN</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/diagnostics10030139" target="_blank" >10.3390/diagnostics10030139</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Video Laryngoscopic Intubation Using the King Vision (TM) Laryngoscope in a Simulated Cervical Spine Trauma: A Comparison Between Non-Channeled and Channeled Disposable Blades
Popis výsledku v původním jazyce
Videolaryngoscopes may reduce cervical spine movement during tracheal intubation in patients with neck trauma. This manikin study aimed to compare the performance of disposable non-channeled and channeled blades of the King Vision (TM) videolaryngoscope in simulated cervical spine injury. Fifty-eight anesthesiologists in training intubated the TruMan manikin with the neck immobilized using each blade in a randomized order. The primary outcome was the time needed for tracheal intubation, secondary aims included total success rate, the time required for visualization of the larynx, number of attempts, view of the vocal cords, and subjective assessment of both methods. Intubation time with the channeled blade was shorter, with a median time of 13 s (IQR 9-19) vs. 23 s (14.5-37.5), p < 0.001, while times to visualization of the larynx were similar in both groups (p = 0.54). Success rates were similar in both groups, but intubation with the non-channeled blade required more attempts (1.52 vs. 1.05; p < 0.001). The participants scored the intubation features of the channeled blade significantly higher, while visualization features were scored similarly in both groups. Both blades of the King Vision (TM) videolaryngoscope are reliable intubation devices in a simulated cervical spine injury in a manikin model when inserted by non-experienced operators. The channeled blade allowed faster intubation of the trachea.
Název v anglickém jazyce
Video Laryngoscopic Intubation Using the King Vision (TM) Laryngoscope in a Simulated Cervical Spine Trauma: A Comparison Between Non-Channeled and Channeled Disposable Blades
Popis výsledku anglicky
Videolaryngoscopes may reduce cervical spine movement during tracheal intubation in patients with neck trauma. This manikin study aimed to compare the performance of disposable non-channeled and channeled blades of the King Vision (TM) videolaryngoscope in simulated cervical spine injury. Fifty-eight anesthesiologists in training intubated the TruMan manikin with the neck immobilized using each blade in a randomized order. The primary outcome was the time needed for tracheal intubation, secondary aims included total success rate, the time required for visualization of the larynx, number of attempts, view of the vocal cords, and subjective assessment of both methods. Intubation time with the channeled blade was shorter, with a median time of 13 s (IQR 9-19) vs. 23 s (14.5-37.5), p < 0.001, while times to visualization of the larynx were similar in both groups (p = 0.54). Success rates were similar in both groups, but intubation with the non-channeled blade required more attempts (1.52 vs. 1.05; p < 0.001). The participants scored the intubation features of the channeled blade significantly higher, while visualization features were scored similarly in both groups. Both blades of the King Vision (TM) videolaryngoscope are reliable intubation devices in a simulated cervical spine injury in a manikin model when inserted by non-experienced operators. The channeled blade allowed faster intubation of the trachea.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30223 - Anaesthesiology
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Diagnostics [online]
ISSN
2075-4418
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
8
Strana od-do
139
Kód UT WoS článku
000524293700033
EID výsledku v databázi Scopus
2-s2.0-85081347635