A novel accurate LC-MS/MS method for quantitative determination of Z-lumirubin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10414639" target="_blank" >RIV/00216208:11110/20:10414639 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/20:00117827 RIV/00064165:_____/20:10414639
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qiWh~yLIYZ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qiWh~yLIYZ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-020-61280-z" target="_blank" >10.1038/s41598-020-61280-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A novel accurate LC-MS/MS method for quantitative determination of Z-lumirubin
Popis výsledku v původním jazyce
Although phototherapy (PT) is a standard treatment for neonatal jaundice, no validated clinical methods for determination of bilirubin phototherapy products are available. Thus, the aim of our study was to establish a such method for clinical use. To achieve this aim, a LC-MS/MS assay for simultaneous determination of Z-lumirubin (LR) and unconjugated bilirubin (UCB) was conducted. LR was purified after irradiation of UCB at 460 nm. The assay was tested on human sera from PT-treated neonates. Samples were separated on a HPLC system with a triple quadrupole mass spectrometer detector. The instrument response was linear up to 5.8 and 23.4 mg/dL for LR and UCB, respectively, with submicromolar limits of detection and validity parameters relevant for use in clinical medicine. Exposure of newborns to PT raised serum LR concentrations three-fold (p < 0.01), but the absolute concentrations were low (0.37 +/- 0.16 mg/dL), despite a dramatic decrease of serum UCB concentrations (13.6 +/- 2.2 vs. 10.3 +/- 3.3 mg/dL, p < 0.01). A LC-MS/MS method for the simultaneous determination of LR and UCB in human serum was established and validated for clinical use. This method should help to monitor neonates on PT, as well as to improve our understanding of both the kinetics and biology of bilirubin phototherapy products.
Název v anglickém jazyce
A novel accurate LC-MS/MS method for quantitative determination of Z-lumirubin
Popis výsledku anglicky
Although phototherapy (PT) is a standard treatment for neonatal jaundice, no validated clinical methods for determination of bilirubin phototherapy products are available. Thus, the aim of our study was to establish a such method for clinical use. To achieve this aim, a LC-MS/MS assay for simultaneous determination of Z-lumirubin (LR) and unconjugated bilirubin (UCB) was conducted. LR was purified after irradiation of UCB at 460 nm. The assay was tested on human sera from PT-treated neonates. Samples were separated on a HPLC system with a triple quadrupole mass spectrometer detector. The instrument response was linear up to 5.8 and 23.4 mg/dL for LR and UCB, respectively, with submicromolar limits of detection and validity parameters relevant for use in clinical medicine. Exposure of newborns to PT raised serum LR concentrations three-fold (p < 0.01), but the absolute concentrations were low (0.37 +/- 0.16 mg/dL), despite a dramatic decrease of serum UCB concentrations (13.6 +/- 2.2 vs. 10.3 +/- 3.3 mg/dL, p < 0.01). A LC-MS/MS method for the simultaneous determination of LR and UCB in human serum was established and validated for clinical use. This method should help to monitor neonates on PT, as well as to improve our understanding of both the kinetics and biology of bilirubin phototherapy products.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30209 - Paediatrics
Návaznosti výsledku
Projekt
<a href="/cs/project/NV18-07-00342" target="_blank" >NV18-07-00342: Studium degradačních produktů bilirubinu vznikajících při fototerapii novorozenecké žloutenky</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
4411
Kód UT WoS článku
000563374600009
EID výsledku v databázi Scopus
2-s2.0-85081602730