Pentamethinium Salts Nanocomposite for Electrochemical Detection of Heparin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F21%3A10433413" target="_blank" >RIV/00216208:11110/21:10433413 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22340/21:43922025
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=iMSX5VuPml" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=iMSX5VuPml</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ma14185357" target="_blank" >10.3390/ma14185357</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pentamethinium Salts Nanocomposite for Electrochemical Detection of Heparin
Popis výsledku v původním jazyce
This study presents a simple route to heparin detection and develops a voltammetric approach using supramolecular principles and nanomaterials. Nanocomposites, including gold nanoparticles (AuNPs) and gamma-substituted pentamethinium salts (PMS) deposited on a glass carbon (GC) electrode surface (GC/AuNPs/PMS) and covered by a plasticized poly(vinyl chloride) (PVC) membrane, are proposed for heparin detection. The conductivity of the nonconducting PVC-plasticized membrane is guaranteed by AuNPs, and the selectivity is provided by the interaction between gamma-substituted PMS and anionic analytes. In order to extend the linear range, it is necessary to apply a solvent compatible with PVC-plasticized membrane, namely tetrahydrofuran. The proposed voltammetric sensor showed a concentration dependence from 1.72 up to 45.02 IU mL(-1) heparin and was used for heparin detection in saline and biological samples with recovery of 95.1-100.9%.
Název v anglickém jazyce
Pentamethinium Salts Nanocomposite for Electrochemical Detection of Heparin
Popis výsledku anglicky
This study presents a simple route to heparin detection and develops a voltammetric approach using supramolecular principles and nanomaterials. Nanocomposites, including gold nanoparticles (AuNPs) and gamma-substituted pentamethinium salts (PMS) deposited on a glass carbon (GC) electrode surface (GC/AuNPs/PMS) and covered by a plasticized poly(vinyl chloride) (PVC) membrane, are proposed for heparin detection. The conductivity of the nonconducting PVC-plasticized membrane is guaranteed by AuNPs, and the selectivity is provided by the interaction between gamma-substituted PMS and anionic analytes. In order to extend the linear range, it is necessary to apply a solvent compatible with PVC-plasticized membrane, namely tetrahydrofuran. The proposed voltammetric sensor showed a concentration dependence from 1.72 up to 45.02 IU mL(-1) heparin and was used for heparin detection in saline and biological samples with recovery of 95.1-100.9%.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials [online]
ISSN
1996-1944
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
18
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
5357
Kód UT WoS článku
000700742300001
EID výsledku v databázi Scopus
2-s2.0-85115293947