Amperometrický detektor heparinu: detekční mechanismus a použití při analýze lidské krevní plasmy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F06%3A00040164" target="_blank" >RIV/61388955:_____/06:00040164 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/06:00000185
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Amperometric Sensor for Heparin: Sensing Mechanism and Application in Human Blood Plasma Analysis
Popis výsledku v původním jazyce
Voltammetric measurements of heparin at a rotating glassy carbon (GC) electrode coated with a polyvinylchloride membrane are reported. A spin-coating technique us used to prepare thin membranes (20-40 micrometers) with a composition of 25% (w/w) PVC, 1,1'-dimethylferrocene as a reference electron donor for the GC/membrane interface, nitrophenyl octyl ether (o-NPOE) or bis(2-ethylhexyl) sebacate (DOS) as a plasticizer, and hexadecyltrimethylammonium tetrakis(4-chlorophenyl) borate (HTMATPBCI) or tridodecylmethylammonium tetrakis(4-chlorophenyl) borate (TDMATPBCI) as a background electrolyte. It is shown that the electrodes coated with either the HTMA +/o-NPOE (DOS) or TDMA +/o-NPOE (DOS) membrane provide a comparable amperometric response towards heparin (1-10 U mL-1) in the aqueous solution of 0.1 M LiCl. However, only the membranes formulated with TDMATPBCI can be used for an amperometric assay of heparin in human blood plasma with a detection limit of 0.2 mL-1.
Název v anglickém jazyce
Amperometric Sensor for Heparin: Sensing Mechanism and Application in Human Blood Plasma Analysis
Popis výsledku anglicky
Voltammetric measurements of heparin at a rotating glassy carbon (GC) electrode coated with a polyvinylchloride membrane are reported. A spin-coating technique us used to prepare thin membranes (20-40 micrometers) with a composition of 25% (w/w) PVC, 1,1'-dimethylferrocene as a reference electron donor for the GC/membrane interface, nitrophenyl octyl ether (o-NPOE) or bis(2-ethylhexyl) sebacate (DOS) as a plasticizer, and hexadecyltrimethylammonium tetrakis(4-chlorophenyl) borate (HTMATPBCI) or tridodecylmethylammonium tetrakis(4-chlorophenyl) borate (TDMATPBCI) as a background electrolyte. It is shown that the electrodes coated with either the HTMA +/o-NPOE (DOS) or TDMA +/o-NPOE (DOS) membrane provide a comparable amperometric response towards heparin (1-10 U mL-1) in the aqueous solution of 0.1 M LiCl. However, only the membranes formulated with TDMATPBCI can be used for an amperometric assay of heparin in human blood plasma with a detection limit of 0.2 mL-1.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F04%2F0424" target="_blank" >GA203/04/0424: Elektrochemie biomedicinálně významných polyiontů na rozhraní dvou nemísitelných roztoků elektrolytů s aplikacemi v analýze léčiv</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
18
Číslo periodika v rámci svazku
13-14
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
1329-1338
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—