Effect of tetraalkylammonium cations on amperometric detection of heparin at a polarized water/ionic liquid membrane interface
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F13%3A00392976" target="_blank" >RIV/61388955:_____/13:00392976 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/13:43908195
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of tetraalkylammonium cations on amperometric detection of heparin at a polarized water/ionic liquid membrane interface
Popis výsledku v původním jazyce
Amperometric detection of heparin, which combines the spontaneous extraction of heparin into the ionic liquid (IL) membrane with its potential-driven stripping, is studied using IL composed of the tetradodecylammonium (TDDA+) cation and tetrakis[3,5-bis(trifluoro-methyl)phenyl]borate (TFPB-). In contrast to the IL membrane composed of tridodecylmethylammonium cation (TDMA+) and TFPB-, no promotion effect of the tetrapentylammonium cation (TPeA+) is observed. The absence of the effect is ascribed to a much weaker ion association between heparin and TDDA+, which does not support the accumulation of heparin into the IL phase.
Název v anglickém jazyce
Effect of tetraalkylammonium cations on amperometric detection of heparin at a polarized water/ionic liquid membrane interface
Popis výsledku anglicky
Amperometric detection of heparin, which combines the spontaneous extraction of heparin into the ionic liquid (IL) membrane with its potential-driven stripping, is studied using IL composed of the tetradodecylammonium (TDDA+) cation and tetrakis[3,5-bis(trifluoro-methyl)phenyl]borate (TFPB-). In contrast to the IL membrane composed of tridodecylmethylammonium cation (TDMA+) and TFPB-, no promotion effect of the tetrapentylammonium cation (TPeA+) is observed. The absence of the effect is ascribed to a much weaker ion association between heparin and TDDA+, which does not support the accumulation of heparin into the IL phase.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F11%2F0707" target="_blank" >GAP206/11/0707: Voltametrické studium nových iontových kapalin pro jejich využití v kapilární elektroforéze</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXIII. Moderní elektrochemické metody. Sborník přednášek
ISBN
978-80-905221-1-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
167-171
Název nakladatele
Best servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
20. 5. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce