Transfer of heparin polyion across a polarized water/ionic liquid membrane interface
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F12%3A00379900" target="_blank" >RIV/61388955:_____/12:00379900 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/12:43906467
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.elecom.2012.08.007" target="_blank" >http://dx.doi.org/10.1016/j.elecom.2012.08.007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.elecom.2012.08.007" target="_blank" >10.1016/j.elecom.2012.08.007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Transfer of heparin polyion across a polarized water/ionic liquid membrane interface
Popis výsledku v původním jazyce
Cyclic voltammetry is used to investigate the transfer of heparin polyion across the interface between water and the ionic liquid (IL) membrane composed of tridodecylmethylammonium cation (TDMA+) and tetrakis[3,5-bis(trifluoromethyl) phenyl]borate anion(TFPB). Study reveals a tunable effect of the semihydrophobic tetraalkylammonium cations (TAA+) present at trace concentrations in the aqueous solution containing heparin. Theoretical considerations based on the mixed-potential concept and experimental evidence suggest that the TAA+ cations promote the extraction of heparin into the IL phase, from which heparin can be stripped off by applied potential providing a well-separated current signal. A new method for the amperometric detection of heparin is proposed.
Název v anglickém jazyce
Transfer of heparin polyion across a polarized water/ionic liquid membrane interface
Popis výsledku anglicky
Cyclic voltammetry is used to investigate the transfer of heparin polyion across the interface between water and the ionic liquid (IL) membrane composed of tridodecylmethylammonium cation (TDMA+) and tetrakis[3,5-bis(trifluoromethyl) phenyl]borate anion(TFPB). Study reveals a tunable effect of the semihydrophobic tetraalkylammonium cations (TAA+) present at trace concentrations in the aqueous solution containing heparin. Theoretical considerations based on the mixed-potential concept and experimental evidence suggest that the TAA+ cations promote the extraction of heparin into the IL phase, from which heparin can be stripped off by applied potential providing a well-separated current signal. A new method for the amperometric detection of heparin is proposed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F11%2F0707" target="_blank" >GAP206/11/0707: Voltametrické studium nových iontových kapalin pro jejich využití v kapilární elektroforéze</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrochemistry Communications
ISSN
1388-2481
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
OCT 2012
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
3
Strana od-do
25-27
Kód UT WoS článku
000310943100007
EID výsledku v databázi Scopus
—