Influence of Isomeric Composition and Sample Handling on the Liquid Density of Hydrofluorethers Measured by Vibrating Tube Densimeter at 0.1 MPa
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F23%3A10467650" target="_blank" >RIV/00216208:11110/23:10467650 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=lX9v9V4~.R" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=lX9v9V4~.R</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10765-023-03247-6" target="_blank" >10.1007/s10765-023-03247-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Isomeric Composition and Sample Handling on the Liquid Density of Hydrofluorethers Measured by Vibrating Tube Densimeter at 0.1 MPa
Popis výsledku v původním jazyce
Hydrofluoroethers (HFEs) represent a new family of promising engineering fluids suitable for technical cleaning and cooling of electronic and magnetic devices or as admixtures in refrigerant blends. Here, we report accurate data for the liquid density at 0.1 MPa and temperatures from 273.15K to 343.15K for a series of five HFEs, namely, HFE-7000, HFE-7100, HFE-7200, HFE-7300, and HFE-7500. A highly sensitive vibrating tube densimeter with a borosilicate glass U-tube calibrated according to the procedure by Prokopova et al. (J Chem Thermodyn 173:106855, 2022) provided density data with an expanded uncertainty ( k = 2) of 0.13 kg center dot m(-3). Influences such as sample degassing, water content, or sample temperature before its dosing into the densimeter are discussed. Thanks to the high sensitivity of the used densimeter, an unexpected shift in the density of different HFE-7100 and HFE-7200 liquid samples was detected. Unlike other HFEs, HFE-7100 and HFE-7200 are mixtures of two hardly separable isomers, which were so far considered having identical thermophysical properties. Utilizing nuclear magnetic resonance spectroscopy, the ratio of n-isomer and iso-isomer was inspected for various liquid samples. In the range of iso-isomer mole fraction from 0.61 to 0.77, the new measurements revealed density differences of more than 5 kg center dot m(-3) in case of HFE-7100 and of about 3 kg center dot m(-3) in case of HFE-7200. Consequently, for some applications, the properties of different HFE isomers cannot be considered identical. The Rackett-type correlation for the saturated liquid density was fitted using the new and the literature data.
Název v anglickém jazyce
Influence of Isomeric Composition and Sample Handling on the Liquid Density of Hydrofluorethers Measured by Vibrating Tube Densimeter at 0.1 MPa
Popis výsledku anglicky
Hydrofluoroethers (HFEs) represent a new family of promising engineering fluids suitable for technical cleaning and cooling of electronic and magnetic devices or as admixtures in refrigerant blends. Here, we report accurate data for the liquid density at 0.1 MPa and temperatures from 273.15K to 343.15K for a series of five HFEs, namely, HFE-7000, HFE-7100, HFE-7200, HFE-7300, and HFE-7500. A highly sensitive vibrating tube densimeter with a borosilicate glass U-tube calibrated according to the procedure by Prokopova et al. (J Chem Thermodyn 173:106855, 2022) provided density data with an expanded uncertainty ( k = 2) of 0.13 kg center dot m(-3). Influences such as sample degassing, water content, or sample temperature before its dosing into the densimeter are discussed. Thanks to the high sensitivity of the used densimeter, an unexpected shift in the density of different HFE-7100 and HFE-7200 liquid samples was detected. Unlike other HFEs, HFE-7100 and HFE-7200 are mixtures of two hardly separable isomers, which were so far considered having identical thermophysical properties. Utilizing nuclear magnetic resonance spectroscopy, the ratio of n-isomer and iso-isomer was inspected for various liquid samples. In the range of iso-isomer mole fraction from 0.61 to 0.77, the new measurements revealed density differences of more than 5 kg center dot m(-3) in case of HFE-7100 and of about 3 kg center dot m(-3) in case of HFE-7200. Consequently, for some applications, the properties of different HFE isomers cannot be considered identical. The Rackett-type correlation for the saturated liquid density was fitted using the new and the literature data.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10600 - Biological sciences
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Thermophysics
ISSN
0195-928X
e-ISSN
1572-9567
Svazek periodika
44
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
21
Strana od-do
139
Kód UT WoS článku
001049276900002
EID výsledku v databázi Scopus
2-s2.0-85168415137