The performance of the contactless conductivity (C4D) and diode array photometric (DAD) detectors has been compared for CE separations of creatinine, arginine and 3-methylhistidine in acetic acid background electrolytes. The contactless conductivity detector response has also been modeled. It has been found that the two detectors provide similar responses and can readily be used for dual CE detection. Changes in the acetic acid concentration affect the C4D noise less than the DAD noise, but their effecton the C4D response to the analytes is greater than with DAD. In general, C4D provides better detection results at higher acetic acid concentrations, while DAD is more sensitive and reliable at very low ones. Capillaries with greater internal diametersare preferable for both detectors, provided that the separation efficiency is not adversely affected. Acetic acid is a suitable background electrolyte for CE separations of small, basic organic molecules.
Název v anglickém jazyce
A Comparison of the Properties of Contactless Conductivity and Diode-Array Photometric Detectors in Analyses of Low-Molecular, Biologically Active Substances by Capillary Electrophoresis in Acetic Acid Solutions
Popis výsledku anglicky
The performance of the contactless conductivity (C4D) and diode array photometric (DAD) detectors has been compared for CE separations of creatinine, arginine and 3-methylhistidine in acetic acid background electrolytes. The contactless conductivity detector response has also been modeled. It has been found that the two detectors provide similar responses and can readily be used for dual CE detection. Changes in the acetic acid concentration affect the C4D noise less than the DAD noise, but their effecton the C4D response to the analytes is greater than with DAD. In general, C4D provides better detection results at higher acetic acid concentrations, while DAD is more sensitive and reliable at very low ones. Capillaries with greater internal diametersare preferable for both detectors, provided that the separation efficiency is not adversely affected. Acetic acid is a suitable background electrolyte for CE separations of small, basic organic molecules.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F07%2F0896" target="_blank" >GA203/07/0896: Rychlé stanovení biologicky aktivních nízkomolekulárních látek v biologickém materiálu pomocí mikrofluidních technik</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000254144500003
EID výsledku v databázi Scopus
—