Degenerative changes and immune response after transcatheter aortic valve implantation. Comparison with surgical aortic valve replacement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F17%3A43911411" target="_blank" >RIV/00216208:11120/17:43911411 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/17:N0000039
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jjcc.2016.03.009" target="_blank" >http://dx.doi.org/10.1016/j.jjcc.2016.03.009</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jjcc.2016.03.009" target="_blank" >10.1016/j.jjcc.2016.03.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Degenerative changes and immune response after transcatheter aortic valve implantation. Comparison with surgical aortic valve replacement
Popis výsledku v původním jazyce
BACKGROUND: Little is known about the valve degeneration process after transcutaneous aortic valve implantations (TAVI) that can have an important impact on patients' long-term prognosis. AIM: To evaluate degenerative changes of TAVI using computed tomography (CT) compared to findings in patients that underwent surgical aortic valve replacement (SAVR). Subsequently, to compare the level of immune and inflammatory markers in both groups and test their possible role in the valve degeneration process. METHODS AND RESULTS: 49 patients after TAVI and 29 patients in the control group after SAVR underwent 2 years of follow-up and 8 patients from the TAVI group and 7 patients after SAVR underwent five years of follow-up. CT was performed in all patients and calcifications on prosthesis cusps in both groups were measured using Agatson calcium score. TAVI patients were older compared to patients who underwent SAVR [82 (62;86) vs. 74 (64;84) years, p<0.001], and had more comorbidities - higher EuroScore I [21.0 (5.0;46.0) vs. 6.15 (2.54;11.17), p<0.001]. TAVI patients had more often concomitant coronary artery disease (69.4% vs. 13.8%, p<0.001) and previous history of cardiac surgery (32.7% vs. 0.0%, p<0.001). Slight calcifications (mean Agatson score 50.76) on prosthetic cusps were found in 2 patients 4-5 years after TAVI and in 1 patient 2 years after SAVR (p=NS). Even though significant differences were found in values of tumor necrosis factor-α and E-selectin before, 1 year, and 2 years after implantation, no significant changes in values of inflammatory markers were observed during follow-up period in both groups of patients. Detailed analysis revealed no significant difference between values of inflammatory markers of patients with and without calcifications present on CT. CONCLUSION: Minimal degenerative changes on TAVI prosthesis were observed in mid- and long-term follow-up. Systemic immune response did not differ between patients after TAVI and SAVR.
Název v anglickém jazyce
Degenerative changes and immune response after transcatheter aortic valve implantation. Comparison with surgical aortic valve replacement
Popis výsledku anglicky
BACKGROUND: Little is known about the valve degeneration process after transcutaneous aortic valve implantations (TAVI) that can have an important impact on patients' long-term prognosis. AIM: To evaluate degenerative changes of TAVI using computed tomography (CT) compared to findings in patients that underwent surgical aortic valve replacement (SAVR). Subsequently, to compare the level of immune and inflammatory markers in both groups and test their possible role in the valve degeneration process. METHODS AND RESULTS: 49 patients after TAVI and 29 patients in the control group after SAVR underwent 2 years of follow-up and 8 patients from the TAVI group and 7 patients after SAVR underwent five years of follow-up. CT was performed in all patients and calcifications on prosthesis cusps in both groups were measured using Agatson calcium score. TAVI patients were older compared to patients who underwent SAVR [82 (62;86) vs. 74 (64;84) years, p<0.001], and had more comorbidities - higher EuroScore I [21.0 (5.0;46.0) vs. 6.15 (2.54;11.17), p<0.001]. TAVI patients had more often concomitant coronary artery disease (69.4% vs. 13.8%, p<0.001) and previous history of cardiac surgery (32.7% vs. 0.0%, p<0.001). Slight calcifications (mean Agatson score 50.76) on prosthetic cusps were found in 2 patients 4-5 years after TAVI and in 1 patient 2 years after SAVR (p=NS). Even though significant differences were found in values of tumor necrosis factor-α and E-selectin before, 1 year, and 2 years after implantation, no significant changes in values of inflammatory markers were observed during follow-up period in both groups of patients. Detailed analysis revealed no significant difference between values of inflammatory markers of patients with and without calcifications present on CT. CONCLUSION: Minimal degenerative changes on TAVI prosthesis were observed in mid- and long-term follow-up. Systemic immune response did not differ between patients after TAVI and SAVR.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Cardiology
ISSN
0914-5087
e-ISSN
—
Svazek periodika
69
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
483-488
Kód UT WoS článku
000394195800072
EID výsledku v databázi Scopus
2-s2.0-84968662274