Noninvasive identification of local disorders of electrogenesis in ventricular arrhythmias
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F17%3A43920119" target="_blank" >RIV/00216208:11120/17:43920119 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/17:00308188
Výsledek na webu
<a href="https://www.sks.sk/system/files/cardiol_2017_1_39.pdf" target="_blank" >https://www.sks.sk/system/files/cardiol_2017_1_39.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
slovinština
Název v původním jazyce
Neinvazívna identifikácia lokálnych porúch elektrogenézy pri komorových arytmiách
Popis výsledku v původním jazyce
V štúdii na piatich pacientoch bolo neinvazívne lokalizované miesto vzniku ektopickej komorovej akti- vity pomocou povrchového izointegrálového mapovania hrudníka a riešenia inverznej úlohy elektrokardiogra e do jedného dipólu. Študovala sa presnosť riešenia inverznej úlohy pri použití troch rôznych modelov hrudníka vytvorených na základe CT vyšetrenia: homogénny model, model s uvažovaním nehomogenít pľúc a dutín srdcových komôr a nehomogénny model, ktorý zahŕňal pľúca, dutiny komôr a predsiení, aortu a pľúcnu artériu. Riešenie bolo stabilnejšie, ak sa použil homogénny model, ale u niektorých pacientov bola pozícia elektrického dipólu, ktorý predstavoval zdroj ektopickej aktivity, posunutá voči výsledkom získaným pri použití nehomogénnych modelov. Výsledky pre oba nehomogénne modely nemali významne rozdielne rozptyly, ale lokalizácia zdroja bola lepšia, ak sa použil model, ktorý zahŕňal aj nehomogenity predsiení a artérií. Dosiahnuté výsledky naznačujú, že neinvazívnu predoperačnú lokalizáciu miesta vzniku ektopickej aktivity by bolo možné použiť na skrátenie času ablačnej terapie a zvýšenie jej úspešnosti.
Název v anglickém jazyce
Noninvasive identification of local disorders of electrogenesis in ventricular arrhythmias
Popis výsledku anglicky
In a study on five patients the focus of premature ectopic ventricular activity was assessed noninvasively using integral body surface potential maps and inverse solution in terms of a single dipole. Precision of the inverse solution was studied using three different torso models: homogeneous torso model, torso model including the inhomogeneities of lungs and heart ventricles, and inhomogeneous torso model including lungs, heart ventricles and atria, aorta and pulmonary artery. The solution was more stable when the homogeneous model was used. However, in some patients the location of the resulting dipole representing the focus of ectopic activity was shifted between solutions using the homogeneous and inhomogeneous models. Comparison of solutions with inhomogeneous torso models did not show significantly different dispersions, but localization of the focus was better when a torso model including atria and arteries was used. The obtained results suggest that noninvasive localization of the ectopic focus can be used to shorten the time needed for successful ablation and to increase its success rate.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cardiology Letters
ISSN
1338-3655
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
8
Strana od-do
39-46
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85013609300