Evaluation of extended depth-of-focus hydrophobic intraocular lens with an optic concept based on combination of high-order aberrations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F23%3A43926104" target="_blank" >RIV/00216208:11120/23:43926104 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1177/25158414231200108" target="_blank" >https://doi.org/10.1177/25158414231200108</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/25158414231200108" target="_blank" >10.1177/25158414231200108</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of extended depth-of-focus hydrophobic intraocular lens with an optic concept based on combination of high-order aberrations
Popis výsledku v původním jazyce
BACKGROUND: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) provide a continuous range of uncorrected vision at different distances. OBJECTIVE: To assess visual acuity, refractive outcomes, and patient satisfaction after cataract surgery using the LuxSmart EDOF IOL (Bausch+Lomb). DESIGN: A two-center, prospective observational clinical study. METHODS: This study includes patients who have undergone bilateral phacoemulsification with bilateral implantation of the LuxSmart EDOF IOL, with the aim of achieving emmetropia. Visual acuity (VA) and subjective refraction were obtained in all patients preoperatively and at 1 week, 1 month, 3 months, and 6 months postoperatively. Subjective measures were obtained using the Catquest-9SF questionnaire and the Patient-Reported Spectacle Independence Questionnaire (PRSIQ). Contrast sensitivity and a glare assessment were undertaken postoperatively. Safety outcomes were additionally assessed. RESULTS: Sixty eyes from thirty patients were recruited for this study. The mean spherical equivalent was 1.04 +- 1.67 D preoperatively and -0.30 +- 0.46 D at 6 months. Monocular uncorrected distance VA was 0.57 +- 0.32 (logMAR) preoperatively and 0.09 +- 0.12 (logMAR) at 6 months. Mean 6-month monocular uncorrected VA was 0.11 +- 0.13, 0.12 +- 0.15, and 0.31 +- 0.15 (logMAR) at 80, 66, and 40 cm, respectively. More than 90% of patients were either fairly or very satisfied with their vision. There was one case of suspected vitreomacular traction postoperatively. CONCLUSION: The LuxSmart EDOF IOL offers good refractive, VA, and safety outcomes. The single elongated focal point designed to enhance the DOF shows good results for VA and patient satisfaction.
Název v anglickém jazyce
Evaluation of extended depth-of-focus hydrophobic intraocular lens with an optic concept based on combination of high-order aberrations
Popis výsledku anglicky
BACKGROUND: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) provide a continuous range of uncorrected vision at different distances. OBJECTIVE: To assess visual acuity, refractive outcomes, and patient satisfaction after cataract surgery using the LuxSmart EDOF IOL (Bausch+Lomb). DESIGN: A two-center, prospective observational clinical study. METHODS: This study includes patients who have undergone bilateral phacoemulsification with bilateral implantation of the LuxSmart EDOF IOL, with the aim of achieving emmetropia. Visual acuity (VA) and subjective refraction were obtained in all patients preoperatively and at 1 week, 1 month, 3 months, and 6 months postoperatively. Subjective measures were obtained using the Catquest-9SF questionnaire and the Patient-Reported Spectacle Independence Questionnaire (PRSIQ). Contrast sensitivity and a glare assessment were undertaken postoperatively. Safety outcomes were additionally assessed. RESULTS: Sixty eyes from thirty patients were recruited for this study. The mean spherical equivalent was 1.04 +- 1.67 D preoperatively and -0.30 +- 0.46 D at 6 months. Monocular uncorrected distance VA was 0.57 +- 0.32 (logMAR) preoperatively and 0.09 +- 0.12 (logMAR) at 6 months. Mean 6-month monocular uncorrected VA was 0.11 +- 0.13, 0.12 +- 0.15, and 0.31 +- 0.15 (logMAR) at 80, 66, and 40 cm, respectively. More than 90% of patients were either fairly or very satisfied with their vision. There was one case of suspected vitreomacular traction postoperatively. CONCLUSION: The LuxSmart EDOF IOL offers good refractive, VA, and safety outcomes. The single elongated focal point designed to enhance the DOF shows good results for VA and patient satisfaction.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Therapeutic Advances in Ophthalmology
ISSN
2515-8414
e-ISSN
2515-8414
Svazek periodika
15
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
25158414231200108
Kód UT WoS článku
001074804400001
EID výsledku v databázi Scopus
2-s2.0-85173653123