Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F25%3A43927676" target="_blank" >RIV/00216208:11120/25:43927676 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.aca.2024.343325" target="_blank" >https://doi.org/10.1016/j.aca.2024.343325</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2024.343325" target="_blank" >10.1016/j.aca.2024.343325</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review
Popis výsledku v původním jazyce
The review focuses on the design of detection cells, the use of microcontrollers for processing and evaluation of the detection signal, and the development of multi-detection systems for electromigration, liquid chromatography, flow-through and microfluidic techniques. A separate section is the introduction of modern 3D printing techniques and the use of new printing materials for the design of multidetection systems. In addition to traditional utilisation in separation techniques, new versions of contactless conductivity detectors are finding applications in FIA, SIA, portable and paper based analytical systems or as independent sensors. Applicationwise, C4Ds find new use in gas detection, segmented flow monitoring, as part of point of care devices, and in many other biomedical, environmental, agricultural and industrial applications.
Název v anglickém jazyce
Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review
Popis výsledku anglicky
The review focuses on the design of detection cells, the use of microcontrollers for processing and evaluation of the detection signal, and the development of multi-detection systems for electromigration, liquid chromatography, flow-through and microfluidic techniques. A separate section is the introduction of modern 3D printing techniques and the use of new printing materials for the design of multidetection systems. In addition to traditional utilisation in separation techniques, new versions of contactless conductivity detectors are finding applications in FIA, SIA, portable and paper based analytical systems or as independent sensors. Applicationwise, C4Ds find new use in gas detection, segmented flow monitoring, as part of point of care devices, and in many other biomedical, environmental, agricultural and industrial applications.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA22-22398S" target="_blank" >GA22-22398S: Mikrofluidní a elektronická zařízení pro on-line elektroforetickou analýzu tukové tkáně</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
1873-4324
Svazek periodika
1337
Číslo periodika v rámci svazku
February
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
17
Strana od-do
343325
Kód UT WoS článku
001397308600001
EID výsledku v databázi Scopus
2-s2.0-85206914760