Mikrosensor jako nástroj k detekci těžkých kovů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F08%3A00133466" target="_blank" >RIV/62156489:43210/08:00133466 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Microsensors as a tool to detect heavy metals
Popis výsledku v původním jazyce
To miniaturize the detection systems new technologies and approaches are proposed. Electrochemical sensors based on thick-film technology belong to one of the new technologies. Thick-film technology is based on printing techniques used for various purposes in arts and designs. The aim of this work was to utilize screen-printed carbon electrodes for detection of heavy metal ions (cadmium and lead). For this purpose miniaturized flow cells connected to four-channel mini-potentiostat were employed. The calibration curves measured by cyclic voltammetry were linear in the certain concentration ranges (R2 (Cd) = 0.999; R2 (Pb) = 0.997) with detection limits 500 nM (Cd) and 1uM (Pb). Moreover the sensors fieldwas used for determination of cadmium and lead ions content in plant samples. The content of lead(II) and cadmium(II) ions were elevated markedly in the roots.
Název v anglickém jazyce
Microsensors as a tool to detect heavy metals
Popis výsledku anglicky
To miniaturize the detection systems new technologies and approaches are proposed. Electrochemical sensors based on thick-film technology belong to one of the new technologies. Thick-film technology is based on printing techniques used for various purposes in arts and designs. The aim of this work was to utilize screen-printed carbon electrodes for detection of heavy metal ions (cadmium and lead). For this purpose miniaturized flow cells connected to four-channel mini-potentiostat were employed. The calibration curves measured by cyclic voltammetry were linear in the certain concentration ranges (R2 (Cd) = 0.999; R2 (Pb) = 0.997) with detection limits 500 nM (Cd) and 1uM (Pb). Moreover the sensors fieldwas used for determination of cadmium and lead ions content in plant samples. The content of lead(II) and cadmium(II) ions were elevated markedly in the roots.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA522%2F07%2F0692" target="_blank" >GA522/07/0692: Studium tvorby thiolových sloučenin u rostlin - uplatnění při remediačních technologiích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Toxicology Letters
ISSN
0378-4274
e-ISSN
—
Svazek periodika
180
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
1
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—