Mechanical testing of newly developed biomaterial designed for intra-articular reinforcement of partially ruptured cranial cruciate ligament: ex vivo pig model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F14%3A10292716" target="_blank" >RIV/00216208:11130/14:10292716 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62157124:16170/14:43872758 RIV/62157124:16810/14:43872758 RIV/00216305:26110/14:PU108593
Výsledek na webu
<a href="http://dx.doi.org/10.2754/avb201483010055" target="_blank" >http://dx.doi.org/10.2754/avb201483010055</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2754/avb201483010055" target="_blank" >10.2754/avb201483010055</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mechanical testing of newly developed biomaterial designed for intra-articular reinforcement of partially ruptured cranial cruciate ligament: ex vivo pig model
Popis výsledku v původním jazyce
The study deals with mechanical testing of newly developed material polyethylene terephtalate coated with polycaprolactone nanofibers in combination with biodagradable Hexalon ACL/PCL screws as a new possibility of intra-articular reinforcement of partially ruptured cranial cruciate ligament. Four groups of ex vivo models of pig stifle joints were prepared and tested: a model with intact CCL (group 1), a model with partial CCL rupture (group 2), a model with CCL rupture stabilized with 7 mm Mersilene strip (group 3), and a model with CCL rupture stabilized with 5 mm PET/PCL biomaterial strip (group 4). The models were loaded in the standing angle of 1000 and the maximum load (N) and the shift (mm) were monitored. The mean maximum peak power and the shift were 1266.0 +/- 146.9 N and 13.7 +/- 2.5 mm for group 1, and 1164.7 +/- 228.2 N and 1 6.8 +/- 3.3 mm for group 2, respectively. In all cases after reaching the maximum load, a tibial fracture occurred but never a CCL rupture. In groups
Název v anglickém jazyce
Mechanical testing of newly developed biomaterial designed for intra-articular reinforcement of partially ruptured cranial cruciate ligament: ex vivo pig model
Popis výsledku anglicky
The study deals with mechanical testing of newly developed material polyethylene terephtalate coated with polycaprolactone nanofibers in combination with biodagradable Hexalon ACL/PCL screws as a new possibility of intra-articular reinforcement of partially ruptured cranial cruciate ligament. Four groups of ex vivo models of pig stifle joints were prepared and tested: a model with intact CCL (group 1), a model with partial CCL rupture (group 2), a model with CCL rupture stabilized with 7 mm Mersilene strip (group 3), and a model with CCL rupture stabilized with 5 mm PET/PCL biomaterial strip (group 4). The models were loaded in the standing angle of 1000 and the maximum load (N) and the shift (mm) were monitored. The mean maximum peak power and the shift were 1266.0 +/- 146.9 N and 13.7 +/- 2.5 mm for group 1, and 1164.7 +/- 228.2 N and 1 6.8 +/- 3.3 mm for group 2, respectively. In all cases after reaching the maximum load, a tibial fracture occurred but never a CCL rupture. In groups
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GJ - Choroby a škůdci zvířat, veterinární medicina
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Veterinaria Brno
ISSN
0001-7213
e-ISSN
—
Svazek periodika
83
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
55-60
Kód UT WoS článku
000335204700010
EID výsledku v databázi Scopus
—