Recent trends in the experimental surgical management of a partial anterior cruciate ligament (ACL) rupture in animals show repair of an ACL lesion using novel biomaterials both for biomechanical reinforcement of a partially unstable knee and as suitablescaffolds for bone marrow stem cell therapy in a partial ACL tear. The study deals with mechanical testing of the newly developed ultra-high-molecular-weight polyethylene (UHMWPE) biomaterial anchored to bone with Hexalon biodegradable ACL/PCL screws, as a new possibility of intra-articular reinforcement of a partial ACL tear. Two groups of ex vivo pig knee models were prepared and tested as follows: the model of an ACL tear stabilised with UHMWPE biomaterial using a Hexalon ACL/PCL screw (group 1; n =10) and the model of an ACL tear stabilised with the traditional, and in veterinary medicine used, extracapsular technique involving a monofilament nylon fibre, a clamp and a Securos bone anchor (group 2; n = 11). The models were loaded
Název v anglickém jazyce
Intra-Articular Reinforcement of a Partially Torn Anterior Cruciate Ligament (ACL) Using Newly Developed UHMWPE Biomaterial in Combination with Hexalon ACL/PCL Screws: Ex-vivo Mechanical Testing of an Animal Knee Model
Popis výsledku anglicky
Recent trends in the experimental surgical management of a partial anterior cruciate ligament (ACL) rupture in animals show repair of an ACL lesion using novel biomaterials both for biomechanical reinforcement of a partially unstable knee and as suitablescaffolds for bone marrow stem cell therapy in a partial ACL tear. The study deals with mechanical testing of the newly developed ultra-high-molecular-weight polyethylene (UHMWPE) biomaterial anchored to bone with Hexalon biodegradable ACL/PCL screws, as a new possibility of intra-articular reinforcement of a partial ACL tear. Two groups of ex vivo pig knee models were prepared and tested as follows: the model of an ACL tear stabilised with UHMWPE biomaterial using a Hexalon ACL/PCL screw (group 1; n =10) and the model of an ACL tear stabilised with the traditional, and in veterinary medicine used, extracapsular technique involving a monofilament nylon fibre, a clamp and a Securos bone anchor (group 2; n = 11). The models were loaded
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca
ISSN
0001-5415
e-ISSN
—
Svazek periodika
82
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
222-228
Kód UT WoS článku
000358028700008
EID výsledku v databázi Scopus
—