Feasibility of radioiodine dosimetry using a small field of view gammacamera; pilot study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F15%3A10322184" target="_blank" >RIV/00216208:11130/15:10322184 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064203:_____/15:10322184
Výsledek na webu
<a href="http://www.prolekare.cz/en/clinician-and-technology-journal-article/feasibility-of-radioiodine-dosimetry-using-a-small-field-of-view-gammacamera-pilot-study-57347" target="_blank" >http://www.prolekare.cz/en/clinician-and-technology-journal-article/feasibility-of-radioiodine-dosimetry-using-a-small-field-of-view-gammacamera-pilot-study-57347</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Feasibility of radioiodine dosimetry using a small field of view gammacamera; pilot study
Popis výsledku v původním jazyce
Nowadays, it is crucial to deal with the dosimetry issues in the light of 2013/59 EURATOM recommendation, where it is clearly defined that dosimetry will be required even for the targeted radionuclide therapy (TRT). The aim of this pilot study was to investigate and to verify the possibilities of dosimetry for patients undergoing first Radioiodine therapy (RAIT) using a small single head mobile gamma camera. Camera Solo mobile was used for quantitative imaging of 131I accumulation in remnants of patients' thyroids and 131I accumulating nodes (neck region). Vials with a known activity of 131I were used to calibrate the system. The patientvolunteers were around 3 months after thyreoablation due to thyroid carcinoma. The weight of the accumulating remnants or nodes was established using ultrasound or roughly estimated using phantom measurements. The absorbed doses within remnants or nodes vary from 40 Gy up to 780 Gy with an uncertainty from 25% up to 100% depending mainly on the mass of
Název v anglickém jazyce
Feasibility of radioiodine dosimetry using a small field of view gammacamera; pilot study
Popis výsledku anglicky
Nowadays, it is crucial to deal with the dosimetry issues in the light of 2013/59 EURATOM recommendation, where it is clearly defined that dosimetry will be required even for the targeted radionuclide therapy (TRT). The aim of this pilot study was to investigate and to verify the possibilities of dosimetry for patients undergoing first Radioiodine therapy (RAIT) using a small single head mobile gamma camera. Camera Solo mobile was used for quantitative imaging of 131I accumulation in remnants of patients' thyroids and 131I accumulating nodes (neck region). Vials with a known activity of 131I were used to calibrate the system. The patientvolunteers were around 3 months after thyreoablation due to thyroid carcinoma. The weight of the accumulating remnants or nodes was established using ultrasound or roughly estimated using phantom measurements. The absorbed doses within remnants or nodes vary from 40 Gy up to 780 Gy with an uncertainty from 25% up to 100% depending mainly on the mass of
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika
ISSN
0301-5491
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
82-87
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84957876961