Relationship between method of anastomosis and anastomotic failure after right hemicolectomy and ileo-caecal resection: an international snapshot audit
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F17%3A10366095" target="_blank" >RIV/00216208:11130/17:10366095 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/17:10366095 RIV/00064203:_____/17:10366095 RIV/00064211:_____/17:W0000019
Výsledek na webu
<a href="http://dx.doi.org/10.1111/codi.13646" target="_blank" >http://dx.doi.org/10.1111/codi.13646</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/codi.13646" target="_blank" >10.1111/codi.13646</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Relationship between method of anastomosis and anastomotic failure after right hemicolectomy and ileo-caecal resection: an international snapshot audit
Popis výsledku v původním jazyce
Aim The anastomosis technique used following right-sided colonic resection is widely variable and may affect patient outcome. This study aimed to assess the association between leak and anastomosis technique (stapled vs handsewn). Method This was a prospective, multicentre, international audit including patients undergoing elective or emergency right hemicolectomy or ileo-caecal resection operations over a 2-month period in early 2015. The primary outcome measure was the presence of anastomotic leak within 30 days of surgery, determined using a prespecified definition. Mixed effects logistic regression models were used to assess the association between leak and anastomosis method, adjusting for patient, disease and operative cofactors, with centre included as a random-effect variable. Results This study included 3208 patients, of whom 78.4% (n = 2515) underwent surgery for malignancy and 11.7% (n = 375) underwent surgery for Crohn's disease. An anastomosis was performed in 94.8% (n = 3041) of patients, which was handsewn in 38.9% (n = 1183) and stapled in 61.1% (n = 1858). Patients undergoing hand-sewn anastomosis were more likely to be emergency admissions (20.5% handsewn vs 12.9% stapled) and to undergo open surgery (54.7% handsewn vs 36.6% stapled). The overall anastomotic leak rate was 8.1% (245/3041), which was similar following handsewn (7.4%) and stapled (8.5%) techniques (P = 0.3). After adjustment for cofactors, the odds of a leak were higher for stapled anastomosis (adjusted OR = 1.43; 95% CI: 1.04-1.95; P = 0.03). Conclusion Despite being used in lower-risk patients, stapled anastomosis was associated with an increased anastomotic leak rate in this observational study. Further research is needed to define patient groups in whom a stapled anastomosis is safe.
Název v anglickém jazyce
Relationship between method of anastomosis and anastomotic failure after right hemicolectomy and ileo-caecal resection: an international snapshot audit
Popis výsledku anglicky
Aim The anastomosis technique used following right-sided colonic resection is widely variable and may affect patient outcome. This study aimed to assess the association between leak and anastomosis technique (stapled vs handsewn). Method This was a prospective, multicentre, international audit including patients undergoing elective or emergency right hemicolectomy or ileo-caecal resection operations over a 2-month period in early 2015. The primary outcome measure was the presence of anastomotic leak within 30 days of surgery, determined using a prespecified definition. Mixed effects logistic regression models were used to assess the association between leak and anastomosis method, adjusting for patient, disease and operative cofactors, with centre included as a random-effect variable. Results This study included 3208 patients, of whom 78.4% (n = 2515) underwent surgery for malignancy and 11.7% (n = 375) underwent surgery for Crohn's disease. An anastomosis was performed in 94.8% (n = 3041) of patients, which was handsewn in 38.9% (n = 1183) and stapled in 61.1% (n = 1858). Patients undergoing hand-sewn anastomosis were more likely to be emergency admissions (20.5% handsewn vs 12.9% stapled) and to undergo open surgery (54.7% handsewn vs 36.6% stapled). The overall anastomotic leak rate was 8.1% (245/3041), which was similar following handsewn (7.4%) and stapled (8.5%) techniques (P = 0.3). After adjustment for cofactors, the odds of a leak were higher for stapled anastomosis (adjusted OR = 1.43; 95% CI: 1.04-1.95; P = 0.03). Conclusion Despite being used in lower-risk patients, stapled anastomosis was associated with an increased anastomotic leak rate in this observational study. Further research is needed to define patient groups in whom a stapled anastomosis is safe.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30219 - Gastroenterology and hepatology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Colorectal Disease
ISSN
1462-8910
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
16
Strana od-do
"O296"-"O311"
Kód UT WoS článku
000406961000003
EID výsledku v databázi Scopus
2-s2.0-85026746396