The impact of stapling technique and surgeon specialism on anastomotic failure after right-sided colorectal resection: an international multicentre, prospective audit
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F18%3A10387808" target="_blank" >RIV/00216208:11130/18:10387808 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064203:_____/18:10387808 RIV/00179906:_____/18:10387808
Výsledek na webu
<a href="https://doi.org/10.1111/codi.14308" target="_blank" >https://doi.org/10.1111/codi.14308</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/codi.14308" target="_blank" >10.1111/codi.14308</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The impact of stapling technique and surgeon specialism on anastomotic failure after right-sided colorectal resection: an international multicentre, prospective audit
Popis výsledku v původním jazyce
Aim: There is little evidence to support choice of technique and configuration for stapled anastomoses after right hemicolectomy and ileocaecal resection. This study aimed to determine the relationship between stapling technique and anastomotic failure. Method: Any unit performing gastrointestinal surgery was invited to contribute data on consecutive adult patients undergoing right hemicolectomy or ileocolic resection to this prospective, observational, international, multicentre study. Patients undergoing stapled, side-to-side ileocolic anastomoses were identified and multilevel, multivariable logistic regression analyses were performed to explore factors associated with anastomotic leak. Results: One thousand three hundred and forty-seven patients were included from 200 centres in 32 countries. The overall anastomotic leak rate was 8.3%. Upon multivariate analysis there was no difference in leak rate with use of a cutting stapler for apical closure compared with a noncutting stapler (8.4% vs 8.0%, OR 0.91, 95% CI 0.54-1.53, P = 0.72). Oversewing of the apical staple line, whether in the cutting group (7.9% vs 9.7%, OR 0.87, 95% CI 0.52-1.46, P = 0.60) or noncutting group (8.9% vs 5.7%, OR 1.40, 95% CI 0.46-4.23, P = 0.55) also conferred no benefit in terms of reducing leak rates. Surgeons reporting to be general surgeons had a significantly higher leak rate than those reporting to be colorectal surgeons (12.1% vs 7.3%, OR 1.65, 95% CI 1.04-2.64, P = 0.04). Conclusion: This study did not identify any difference in anastomotic leak rates according to the type of stapling device used to close the apical aspect. In addition, oversewing of the anastomotic staple lines appears to confer no benefit in terms of reducing leak rates. Although general surgeons operated on patients with more high-risk characteristics than colorectal surgeons, a higher leak rate for general surgeons which remained after risk adjustment needs further exploration. Colorectal Disease (C) 2018 The Association of Coloproctology of Great Britain and Ireland
Název v anglickém jazyce
The impact of stapling technique and surgeon specialism on anastomotic failure after right-sided colorectal resection: an international multicentre, prospective audit
Popis výsledku anglicky
Aim: There is little evidence to support choice of technique and configuration for stapled anastomoses after right hemicolectomy and ileocaecal resection. This study aimed to determine the relationship between stapling technique and anastomotic failure. Method: Any unit performing gastrointestinal surgery was invited to contribute data on consecutive adult patients undergoing right hemicolectomy or ileocolic resection to this prospective, observational, international, multicentre study. Patients undergoing stapled, side-to-side ileocolic anastomoses were identified and multilevel, multivariable logistic regression analyses were performed to explore factors associated with anastomotic leak. Results: One thousand three hundred and forty-seven patients were included from 200 centres in 32 countries. The overall anastomotic leak rate was 8.3%. Upon multivariate analysis there was no difference in leak rate with use of a cutting stapler for apical closure compared with a noncutting stapler (8.4% vs 8.0%, OR 0.91, 95% CI 0.54-1.53, P = 0.72). Oversewing of the apical staple line, whether in the cutting group (7.9% vs 9.7%, OR 0.87, 95% CI 0.52-1.46, P = 0.60) or noncutting group (8.9% vs 5.7%, OR 1.40, 95% CI 0.46-4.23, P = 0.55) also conferred no benefit in terms of reducing leak rates. Surgeons reporting to be general surgeons had a significantly higher leak rate than those reporting to be colorectal surgeons (12.1% vs 7.3%, OR 1.65, 95% CI 1.04-2.64, P = 0.04). Conclusion: This study did not identify any difference in anastomotic leak rates according to the type of stapling device used to close the apical aspect. In addition, oversewing of the anastomotic staple lines appears to confer no benefit in terms of reducing leak rates. Although general surgeons operated on patients with more high-risk characteristics than colorectal surgeons, a higher leak rate for general surgeons which remained after risk adjustment needs further exploration. Colorectal Disease (C) 2018 The Association of Coloproctology of Great Britain and Ireland
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Colorectal Disease
ISSN
1462-8910
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
13
Strana od-do
1028-1040
Kód UT WoS článku
000449941600014
EID výsledku v databázi Scopus
2-s2.0-85050459075