Diagnostika Lymské borreliózy při použití EIA metod
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F05%3A00004048" target="_blank" >RIV/00216208:11150/05:00004048 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnosis of Lyme borreliosis using enzyme immunoanalysis
Popis výsledku v původním jazyce
Antiborrelia antibodies in Lyme borreliosis (LB) are mostly detected by enzyme immunoassay (EIA), confirmed by immunoblot (the "two-step system"). In indicated cases, direct evidence of Borrelia burgdorferi is obtained with the PCR method, electron microscopy and cultivation. The "one-step system" of testing for IgM and IgG antibodies in LB is economically preferably, but it requires an EIA kit with more than 90% sensitivity and specificity. The results were verified clinically in all cases, in disputable cases with additional immunoblot (BAG-Med), and analyzed statistically. Conclusions: The best results for a "one-step system" of examinations for antiborrelia antibodies were obtained with the Abbot and Euroimmun EIA kits in our set. A "two-step system" of serological examination could be composed from the basic IgM and IgG examination with a high sensitivity EIA kit (Viroimmun, Test-Line) followed with confirmation of positives by specific immunoblot.
Název v anglickém jazyce
Diagnosis of Lyme borreliosis using enzyme immunoanalysis
Popis výsledku anglicky
Antiborrelia antibodies in Lyme borreliosis (LB) are mostly detected by enzyme immunoassay (EIA), confirmed by immunoblot (the "two-step system"). In indicated cases, direct evidence of Borrelia burgdorferi is obtained with the PCR method, electron microscopy and cultivation. The "one-step system" of testing for IgM and IgG antibodies in LB is economically preferably, but it requires an EIA kit with more than 90% sensitivity and specificity. The results were verified clinically in all cases, in disputable cases with additional immunoblot (BAG-Med), and analyzed statistically. Conclusions: The best results for a "one-step system" of examinations for antiborrelia antibodies were obtained with the Abbot and Euroimmun EIA kits in our set. A "two-step system" of serological examination could be composed from the basic IgM and IgG examination with a high sensitivity EIA kit (Viroimmun, Test-Line) followed with confirmation of positives by specific immunoblot.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EE - Mikrobiologie, virologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medical Science Monitor
ISSN
1234-1010
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
5
Strana od-do
121-125
Kód UT WoS článku
—