Improvement of diagnostic approach to Lyme neuroborreliosis in children by using recombinant antigens in detection of intrathecally produced IgM/IgG
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F16%3A00065596" target="_blank" >RIV/65269705:_____/16:00065596 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/16:00091215
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improvement of diagnostic approach to Lyme neuroborreliosis in children by using recombinant antigens in detection of intrathecally produced IgM/IgG
Popis výsledku v původním jazyce
Background: The purpose of the study was to evaluate new 3rd-generation test kits, EIA Borrelia recombinant IgM and IgG (TestLine, Brno, Czech Republic), in serum and cerebrospinal fluid (CSF) of children with Lyme neuroborreliosis. Methods: Comparison of three tests was used: the whole-cell EIA from Borrelia garinii (EIA 1) was compared with the EIA using recombinant antigens (EIA 2) and immunoblot. In total, 364 samples of serum and CSF were examined. Eighty-six paired sera and CSF samples were evaluated in the first group of children with Lyme neuroborreliosis. The second group consisted of 30 children with probable Lyme neuroborreliosis. Sixty-six samples from children with neuroinfections other than borrelial etiology were used as controls. Results: In the first group of children with proven LNB, EIA 2 gave significantly more positive results for IgG in serum (P = 0.006; OR = 7.5) as in CSF (P < 0.001; OR = 4.5). There was no statistically significant difference in the IgM positivity of serum (P = 0.54; OR = 0.71). EIA 2 determined significantly (P = 0.001; OR = 0.06) less positive results of IgM in CSF in the LNB patients. IgG antibody index (AI) assessed by both methods revealed similar results (P = 0.646; OR = 1.38). Both methods are comparable, but IgM AI assessed by EIA 2 showed significantly less positive results (P < 0.001; OR = 0.04). The differences in the detection of positive IgM/IgG antibodies in serum and CSF did not reach statistical significance either in the groups of children with excluded LNB or in controls. Conclusions: EIA 2 showed better results than EIA 1 and western blot for the detection of positive IgG antibodies in serum and CSF. The difference in the calculation of AI IgG by EIA 1 and EIA 2 was not noticeable in the group of LNB patients. Comparing IgG and IgM AIs calculated from both tests, the sensitivity for EIA 2 was 68% for IgG and 26% for IgM. The specificity is 100% for both tests.
Název v anglickém jazyce
Improvement of diagnostic approach to Lyme neuroborreliosis in children by using recombinant antigens in detection of intrathecally produced IgM/IgG
Popis výsledku anglicky
Background: The purpose of the study was to evaluate new 3rd-generation test kits, EIA Borrelia recombinant IgM and IgG (TestLine, Brno, Czech Republic), in serum and cerebrospinal fluid (CSF) of children with Lyme neuroborreliosis. Methods: Comparison of three tests was used: the whole-cell EIA from Borrelia garinii (EIA 1) was compared with the EIA using recombinant antigens (EIA 2) and immunoblot. In total, 364 samples of serum and CSF were examined. Eighty-six paired sera and CSF samples were evaluated in the first group of children with Lyme neuroborreliosis. The second group consisted of 30 children with probable Lyme neuroborreliosis. Sixty-six samples from children with neuroinfections other than borrelial etiology were used as controls. Results: In the first group of children with proven LNB, EIA 2 gave significantly more positive results for IgG in serum (P = 0.006; OR = 7.5) as in CSF (P < 0.001; OR = 4.5). There was no statistically significant difference in the IgM positivity of serum (P = 0.54; OR = 0.71). EIA 2 determined significantly (P = 0.001; OR = 0.06) less positive results of IgM in CSF in the LNB patients. IgG antibody index (AI) assessed by both methods revealed similar results (P = 0.646; OR = 1.38). Both methods are comparable, but IgM AI assessed by EIA 2 showed significantly less positive results (P < 0.001; OR = 0.04). The differences in the detection of positive IgM/IgG antibodies in serum and CSF did not reach statistical significance either in the groups of children with excluded LNB or in controls. Conclusions: EIA 2 showed better results than EIA 1 and western blot for the detection of positive IgG antibodies in serum and CSF. The difference in the calculation of AI IgG by EIA 1 and EIA 2 was not noticeable in the group of LNB patients. Comparing IgG and IgM AIs calculated from both tests, the sensitivity for EIA 2 was 68% for IgG and 26% for IgM. The specificity is 100% for both tests.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FN - Epidemiologie, infekční nemoci a klinická imunologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Epidemiologie, mikrobiologie, imunologie
ISSN
1210-7913
e-ISSN
—
Svazek periodika
65
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
112-117
Kód UT WoS článku
000383137100007
EID výsledku v databázi Scopus
2-s2.0-84983001793